User Guide KoolProg® http://koolprog.danfoss.com 1.0 Downloading .exe file Conf

User Guide KoolProg® http://koolprog.danfoss.com 1.0 Downloading .exe file Configuring and testing the Danfoss electronic controllers has never been so easy with the new KoolProg PC software. With one KoolProg software, you can now take advantage of new intuitive features such as the selection of favorite parameter lists, writing online as well as offline program files, and monitoring or simulating alarm status activities. These are only some of the new features that will minimize the time R&D and production will spend on development, programming, and testing the Danfoss range of commercial refrigeration controllers. Supported Danfoss products: ETC 1H, EETc/EETa, ERC 111/112/113, ERC 211/213/214, EKE 1A/B/C, AK-CC55. The following instructions will guide you through the installation and first time usage of KoolProg®. Download KoolProgSetup.exe file from the location: http://koolprog.danfoss.com 2.0 System requirements This software is intended for a single user and recommended system requirements as below. OS Windows 7, Windows 10, 32 bit and 64 bit RAM 8 GB RAM HD Space 200 GB and 250 GB Required software MS Office 2010 and above Interface USB 3.0 Macintosh operating system is not supported. Running the setup directly from windows server or network file server is not recommended. 0.0 Introduction Table of contents 0.0 Introduction.....................................................................................................................................................................2 1.0 Downloading .exe file...................................................................................................................................................2 2.0 System requirements....................................................................................................................................................2 3.0 Installing software. .........................................................................................................................................................3 4.0 Connection with controllers. ......................................................................................................................................3 5.0 Starting the program....................................................................................................................................................7 6.0 Set parameters................................................................................................................................................................8 7.0 Copy to controller. ........................................................................................................................................................13 8.0 On-line service. ..............................................................................................................................................................15 9.0 Unknown controller support...................................................................................................................................18 User Guide | KoolProg® 2 | BC227786440099en-000601 © Danfoss | DCS (vt) | 2020.10 1. Connect the KoolKey to PC's USB port 2. Connect the controller to KoolKey using communication cable 4.0 Connection with controllers 3.0 Installing software • Double click on the KoolProg® setup icon Run the installation wizard and follow the onscreen instructions to complete the KoolProg® installation. Note: If you encounter a "Security warning" during installation, please click on "Install this driver software anyway". Fig 1: For EET using KoolKey and cable User Guide | KoolProg® © Danfoss | DCS (vt) | 2020.10 BC227786440099en-000601 | 3 Danfoss 80G8146 To COM  Type C USB  Fig 3: Mass programming of EET and ERC controllers For EET: Insert the KoolKey to PC's USB port and save the config file created using KoolProg in 080Nxxxx.xml format where xxxx are code no. of the controller. For ERC: Connect EKA programming key to USB port of PC/laptop and transfer the file in .erc format from computer to the programming key. 1. Connect USB cable to the PC's USB port 2. Connect the controller. CAUTION: Please ensure that only one controller is connected at any time. Fig 2: For ERC and ETC using Danfoss gateway (Code No. 080G9711) ERC 11X ERC 21X ETC 1HX Interface cable for ERC 11X Interface cable for ERC 21X. TTL port 1.1 port 3.1 port di port Interface cable for ETC Gateway USB A - USB B cable To PC User Guide | KoolProg® 4 | BC227786440099en-000601 © Danfoss | DCS (vt) | 2020.10 For EETa the controller has to be powered with main power or KoolKey must powered with 5 V supply. For EETc the KoolKey has to be mandatorily powered up with 5 V supply. CAUTION: Do not power the KoolKey and controller together. Transferring the file from EKA key to ERC controller: Fig 3a: Transferring to ERC 11X Insert EKA 183A(080G9740) into docking station (080G9701). Place ERC 11X controller on docking station and keep it pressed down until the successful programming indicator turns green. For more details, please refer KoolKey User Guide: BC349529829398en-000102. Transferring the file from KoolKey to EET controller: Fig 3b: Transferring to ERC 21X: Insert EKA 183B (080G9741) into the TTL port of ERC 21X as shown in image below. Press the button to initiate transfer of file from EKA 183B to ERC21X. For more information, please refer to EKA 183B (080G9741) instruction sheet provided in the kit. ERC 21X User Guide | KoolProg® © Danfoss | DCS (vt) | 2020.10 BC227786440099en-000601 | 5 Danfoss 80G8147 To Power bank / 5 V power supply KoolKey EETc/EETa To COM  Termination R-H EKE1x MMIMYK AK-CC55 must be connected to the PC using MMIMYK interface as shown. Power 115 – 230 V AC Display Port AK-CC55 MMIMYK RJ11 Port Power 12 V DC USB mini USB mini To PC To PC Fig 5: Connection for AK-CC55 using interface type MMIMYK (Code No. 080G0073) EKE 1x must be connected to the PC using MMIMYK interface as shown. Power 24 V RJCAN Port RJCAN Port Power 12 V DC Fig 4: Connection for EKE using interface type MMIMYK (Code No. 080G0073) User Guide | KoolProg® 6 | BC227786440099en-000601 © Danfoss | DCS (vt) | 2020.10 To create new parameter setting files either importing from controller or offline. Double click on the desktop icon to launch KoolProg application Select the units you prefer to work with: Metric (°C and bar) Imperial (°F and PSI) Choose the preferred language To program parameter setting file and upgrade firmware in the connected controller To edit settings/trend graphs of controller parameters in real-time. Preferences Help The program’s features Accessibility 5.0 Starting the program Password protection: If the program is password protected, it is possible to specify two different access levels: one with a password and one without a password. Users with a password have access to all features. Users without a password have limited access and may only be able to use the 'Copy to controller' feature. User Guide | KoolProg® © Danfoss | DCS (vt) | 2020.10 BC227786440099en-000601 | 7 This feature allows you to configure parameter settings for your application. Click one of the icons in the right column to create a fresh configuration offline or import settings from a connected controller or open an already saved project. You can see projects you have already created under "Open a recent setting file". 6.0 Set parameters New Create new project by selecting: - Controller type - Part number (code number) - PV (product version) number - SW (software) version Once you have selected a file, you need to name the project. Click 'Finish' to proceed to view and set parameters. Note: Only standard code numbers are available to choose from in the “Code Number” field. To work offline with a non-standard code number (customer specific code number), use one of the following two methods: 1. Connect the controller of same code number with KoolProg using Gateway, and use “Import settings from Controller” to create a configuration file from it. 2. Use “Open” feature to open an existing locally saved file on your PC of same code number and create a new file from it. The new file, saved on your PC locally, can be accessed offline in future without having to connect the controller. User Guide | KoolProg® 8 | BC227786440099en-000601 © Danfoss | DCS (vt) | 2020.10 After "Import completed", save the imported setting file by providing the file name in the pop-up message box. Now the parameter settings can be worked upon offline and can be written back to the controller by pressing "Export" . While working offline, the connected controller is shown grayed out and changed parameter values are not written to the controller until the export button is pressed. Import settings from controller Allows you to import a configuration from connected controller to KoolProg and to modify the parameters offline. Select "Import settings from controller" to import all parameters and its details from the connected controller to the PC. User Guide | KoolProg® © Danfoss | DCS (vt) | 2020.10 BC227786440099en-000601 | 9 "Open" command lets you open setting files already saved to the computer. Once the command is clicked, a window will appear with a list of saved setting files. All projects are stored here in the folder: “KoolProg/Configurations” by default. You can change the default file saving location in "Preferences" . You can also open the setting files you have received from another source and saved in any folder using the browse option. Please note that KoolProg supports multiple file formats (xml, cbk) for different controllers. select the appropriate setting file format of the controller you are using. Note: .erc/.dpf format files of ERC/ETC controller are not visible here. A .erc or .dpf file saved on your PC can be opened in one of the following ways: 1. Select "New Project" and go all the way to Parameter list view of the same controller model. Select Open button to browse and open .erc/.dpf file on your PC. 2. Select "Upload from controller" if you are connected to the same controller online and go to the parameter list view. Select Open button to browse desired .erc/.dpf file and view it in KoolProg. 3. Select "Open" to open any other .xml file of the same controller, reach parameter list view screen, and there select Open button to browse and select .erc/.dpf file to view and edit these files. Import controller model (only for AK-CC55): This allows you to import controller model (.cdf) offline and generate database in uploads/s3/ koolprog-user-guide.pdf

  • 30
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager