legacy humidifier installation amp owners manual r
GENERALAireR RESIDENTIAL AIR TREATMENT PRODUCTS SERIES INSTALLER PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION IS COMPLETE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER FLOW-THROUGH PRECAUTION The installer should be an experienced service technician Disconnect electrical power before BYPASS HUMIDIFIER beginning installation Do not install where temperatures fall below degrees F or where plenum temperatures exceed degrees F When wiring into a multi-speed blower circuit see Step D FOR INSTALLATION ON A VERTICAL INSTALLATION The humidi ?er may be mounted with the outlet to the right or left by inverting the cabinet and PLENUM SURFACE OF ANY FORCED AIR FURNACE reversing the positions of the distributor trough and drain pan The humidi ?er may be mounted on the warm or return air plenum with equal e ?ciency WARM AIR RETURN AIR RETURN AIR RETURN AIR WARM AIR See Typical Installations ADDITIONAL MATERIALS THAT MAY BE NECESSARY diameter plastic supply tubing or copper supply tubing for hot water applications diameter galvanized by-pass pipe electrical wire and wire nuts air pressure switch G F Model suggested DRAIN DRAIN DRAIN HIGH BOY WARM AIR GENERALAireRAC SERIES HIGH EFFICIENCY AIR CLEANER COUNTER-FLOW WARM AIR LOW BOY ALLOW INCHES CLEARANCE ABOVE THIS SURFACE FOR SERVICING Top Of Template TEMPLATE FOR INSTALLING BYPASS HUMIDIFIER FOLLOW INSTRUCTIONS PACKED WITH HUMIDIFIER REMOVE PROTECTIVE PAPER FROM BACK OF TEMPLATE AND STICK IN LEVEL POSITION CENTER PUNCH AND DRILL THE FOUR SIDE MOUNTING HOLES WITH A DIA DRILL HANG HUMIDIFIER FROM FOUR SIDE SCREWS AND INSTALL DRAIN PAN EVAPORATOR PAD AND DISTRIBUTOR TROUGH WHEN INSTALLING ON BASEMENT TYPE FURNACE EXTEND THIS LINE FOR LOCATING HOLE ON ADJACENT PLENUM TIGHTEN SCREWS AND ADJUST HUMIDIFIER UNTIL LEVEL REMARK FOUR REMAINING HOLES IF NECESSARY REMOVE HUMIDIFIER DRILL REMAINING HOLES AND CUT OUT CENTER SECTION OF TEMPLATE CUT ON THIS LINE IF FURNACE JACKET EXTENDS MORE THAN OUTWARD FROM THE PLENUM SURFACE ALLOW CLEARANCE BELOW THIS LINE FOR EASY ACCESS TO DRAIN HOSE CONNECTION TEMPLATE NO - Select location on vertical surface of warm or return air plenum for mounting humidi ?er For plenum sizes to use AD adapter plate and ?ve screws screws in top supplied with DM model only Stick mounting template in place making sure the template is level Do not install humidi ?er or bypass pipe where the blanked o ? ends of a cooling coil will restrict air ow to the humidi ?er Extend horizontal centerline from template to the adjacent plenum Scribe ? circle ? to ? from side of humidi ?er on cabinet centerline using connecting collar as guide Center punch the four side mounting holes on the template and drill with an drill bit Insert four sheet metal screws in the side mounting holes until the heads project about Hang humidi ?er from the four screws and install drain pan evaporator pad and distributor trough Adjust humidi ?er until level and tighten four screws Remark four remaining holes if necessary Remove humidi ?er and drill four remaining holes COPPER TUBI N G PLASTIC TUBI N G
Documents similaires










-
44
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Attribution requise- Détails
- Publié le Dec 23, 2022
- Catégorie Creative Arts / Ar...
- Langue French
- Taille du fichier 71.6kB