Septic guide 1 Design Speci ?cations for Sewage Disposal Systems A Guide to their Design and Maintenance This document provides a single consolidated design criteria for the following documents referenced in the Sewage Disposal Systems Regulation ? Septic

Design Speci ?cations for Sewage Disposal Systems A Guide to their Design and Maintenance This document provides a single consolidated design criteria for the following documents referenced in the Sewage Disposal Systems Regulation ? Septic Systems in the Yukon Design Speci ?cations for the Septic Tank and Soil Absorption System Section and ? Sewage Holding Tank Standards Section No person shall construct install enlarge rebuild substantially repair or connect to an existing system any sewage disposal system or any part thereof or cause the same to be done without ?rst obtaining a written permit from a health o ?cer Sewage Disposal Systems Regulation Design Speci ?cations for Sewage Disposal Systems JAUP RNIEL Table of Contents Septic Tanks and Sewage Holding Tanks Soil Absorption Systems Speci ?cations That Apply To All Soil-Absorption Systems Sizing Your Absorption Bed or Trench Determining the Quantity of Drainrock Chamber Guidelines Sewage Pump-up Systems Guidelines Sewage Pump-Up Systems Guidelines for Soils Investigation and Percolation Tests Photographic Record of the Stages of Installation of a Sewage Disposal System Application Submission Requirements Getting Your System Approved Appendix A ?? Estimated Sewage Flows Per Day Appendix B ?? Calculating the Soil Absorption Area Based on the Percolation Test Appendix C ?? Absorption Bed Sand Filter Appendix D ?? Summary of Setback Distances Table ?? Septic Tank Sizes for Residences Table ?? Length Reduction Factors RF for Wide Absorption Trenches Table ?? Trench Lengths for Chambers Table ?? Textural Properties of Soils Figure Leaching Chambers in Trenches Figure Leaching Chambers in an Absorption Bed Figure Pump-Up System Con ?gurations Figure Pumping Chamber Details Figure Forcemain Connection to Absorption System Figure Bedding and Back ?lling Detail Figure Raised Bed Conceptual Figure Soils Investigation Test Pit and Percolation Test Hole Addendum Septic Systems in the Yukon Construction of a Septic System in Dredge Tailings Septic Tanks and Sewage Holding Tanks WASTEWATER ?? Septic tanks and sewage holding tanks shall receive all wastewater black and grey water from toilets baths showers wash basins sinks and washing machines Water that must be excluded includes run-o ? water from roofs yards foundation drains and other sources not considered to be wastewater industrial processes CONSTRUCTION ?? The construction of septic tanks and sewage holding tanks shall be in accordance with the most current version of CAN CSA- B Design material and manufacturing requirements for prefabricated septic tanks and sewage holding tanks Veri ?cation that this requirement has been met shall be provided Veri ?cation may be in the form of ? Photograph of the CSA certi ?cation stamp on the tank ? Copy of the CSA certi ?cation document speci ?c to that tank ? Report from an Engineer that veri ?es the above construction ? Report from an Engineer that the certi ?cation is equivalent to CAN CSA-B ? Be advised that if tank is to be covered in spray foam this information must be retrieved accordingly NOTE It is not permissible to modify or convert a septic tank from its original design type to

Documents similaires
Bateau de plaisance Bateau de plaisance Cet article n ? est pas rédigé dans un style encyclopédique juin Vous pouvez améliorer sa rédaction La mise en forme de cet article est à améliorer mars La mise en forme du texte ne suit pas les recommandations de W 0 0
Corrige td03 telecharger Architecture des ordinateurs et systèmes d ? exploitation Corrigé du TD Algèbre de BOOLE Marcel Bosc Christophe Dehlinger Beno? t Meister Arnaud Giersch Nicolas Passat Mathieu Haefele Montrer comment l ? opérateur et peut être obt 0 0
Corrige positionnement francais 3e a 1315137 2 0 0
M12 chute libre frottements pdf 1 0 0
introduction a la chimie organique 1 pdf 0 0
Rac12 c lab guide 1 L Oracle Database c Real Application Clusters Lab Guide Copyright ? Oracle and or its a ?liates All rights reserved COracle Database c Real Application Clusters TABLE OF CONTENTS THE WORKSHOP ENVIRONMENT Hardware and Software Importing 0 0
Lecture ce1 semaine 18 mai 0 0
Corrige pont de wheatstone 0 0
Systeme de peinture SOCIETE NATIONALE DES CHEMINS DE FER BELGES SPECIFICATION TECHNIQUE L - SYSTEMES DE PEINTURE DESTINES A LA MISE EN PEINTURE DE STRUCTURES EN ACIER EDITION CSpéci ?cation Technique L- Edition Index Objet Domaine d'application Documents 0 0
Grammaire 12 GRAMMAIRE LE NOM C ? est un mot variable fonctionne avec un déterminant Le nom peut varier en genre et en nombre Le nom fonctionne comme un groupe normal c ? est le mot central du groupe nominal Il est accompagné d ? un déterminant et suivi d 0 0
  • 61
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager