schema du reseaux de control 1
T ASSY REMOTE CONTROL SYS ASSY SYS DE CONTRÔLE À DISTANCE ENGLISH FRENCH THIS DOCUMENT SHALL BE REVISED IN ITS ENTIRETY ALL SHEETS OF THIS DOCUMENT ARE THE SAME REVISION LEVEL AS INDICATED IN THE REVISION BLOCK CE DOCUMENT DOIT ÊTRE ENTIÈREMENT RÉVISÉ TOUTES LES PAGES DE CE DOCUMENT PORTENT LE MÊME NIVEAU DE RÉVISION COMME INDIQUÉ SUR LE BLOC DE RÉVISION ? COPYRIGHT GENERAL ELECTRIC COMPANY PROPRIETARY INFORMATION - THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GENERAL ELECTRIC COMPANY AND MAY NOT BE USED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRIT TEN PERMISSION OF GENERAL ELECTRIC COMPANY ? COPYRIGHT GENERAL ELECTRIC COMPANY INFORMATIONS CONFIDENTIELLES - CE DOCUMENT CONTIENT DES INFORMATIONS QUI SONT LA PROPRIÉTÉ EXCLUSIVE DE GENERAL ELECTRIC COMPANY ET QUI NE SAURAIENT ÊTRE UTILISÉES OU DIV ULGUÉES À DES TIERS SANS L'AUTORISATION ÉCRITE DE GENERAL ELECTRIC COMPANY GE Proprietary Information - Class II Internal US EAR - NLR Informations confidentielles GE - Classe II Interne US EAR - NLR ALL CONTACT INPUTS AND OUTPUTS ARE NORMALLY OPE N CLOSED TO INITIATE FUNCTION IS TRUE UNLESS OTHERWISE SPECIFIED CONTACT INPUTS ARE RATED VDC CONTACT OUTPUTS ARE DRY FORM ??C ? CONTACTS RATED VDC AMP INDUCTIVEK MOMENTARY MEANS THAT THE CONTACT CLOSURE IS TO EXIST FOR A MINIMUM OF SEC K RAISE LOt ER INPUTS WILL BUMP THE INTERNAL SETPOINT ACCORDING TO A FIXED RAMP FUNCTION AS LONG AS THE CONTACT CLOSURE IS PRESENTK TOUTES LES ENTR ES ET SORTIES PAR CONTACT SONT NORMALEMENT OUVERTES FERM ES POUR INITIER CONFIRMER LA FONCTION SAUF MENT ION CONTRAIRE LES ENTR ES PAR CONTACT SONT HOMOLOGU ES V CCK LES SORTIES DE CONTACT SONT DE TYPE SEC EN C ? CAPACIT NOMINALE VDC AMP INDUCTIF MOMENTAN SIGNIFIE QUE LA FERMETURE DU CONTACT DOIT DURER AU MOINS R S AUGMENTER R DUIRE LES ENTR ES POUSSE LE POINT DE CONSIGNE INTERNE SELON UNE FONCTION DE RAMPE FIXE TANT QUE LE CONTACT EST FERM THE MOMENTARY CONTACT INPUTS CAN BE DESIGNATED AS ALWAYS ACTIVE AA OR THEY CAN BE PROGRAMMED TO ONLY BE ACTIVE WHEN REMOTE CONTROL IS SELECTb D BY THE OPERATOR FROM ONE OF THE HMI ? S REMOTE K LES ENTR ES PAR CONTACT MOMENTAN ES PEUVENT TRE CON UES TOUJOURS ACTIVES AA OU TRE PROGRAMM ES POUR TRE ACTIVES UNIQUEMENT LORSQUE LA T L COMMANDE EST S LECTIONN E PAR L'OP RATEUR DEPUIS L'UNE DES HMI DISTANCE K THE CUSTOMER IS RESPONSIBLE FOR UPS UNINTERRUPTIBLE POWER SUPPLY FOR NETWORK EQUIPMENT GE SUGGESTS THAT THE CUSTOMER USE SEPARATE CIRCUITS TO POW ER THE REDUNDANT EQUIPMENT I E ETHERNET St ITCHESK DEVICE APPROX POWER VAC M HZ HMI WITH MONITOR ETHERNET SWITCHES NTP TIME SERVER MAX WATTSF REMOTE SERVER GATEWAY AMPS EACHF AMP EACH LE CLIENT EST RESPONSABLE DES UPS ALIMENTATIONS LECTRIQUES CONTINUES DE L' QUIPEMENT DU R SEAU GE SUGG RE QUE LE CLIENT UTILISE DES CIRCUITS DISTINCTS POUR ALIMENTER L' QUIPEMENT REDONDANT I E COMMUTATEURS ETHERNET K DISPOSITIF PUISSANCE APPROX M Vc a HZ HMI AVEC MONITEURF COMMUTATEURS ETHERNET SERVEUR DE
Documents similaires










-
34
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Aucune attribution requise- Détails
- Publié le Mai 19, 2021
- Catégorie Administration
- Langue French
- Taille du fichier 975.3kB