FibeAir® 1500P FibeAir® IP-MAX FibeAir® IP-MAX2 IDU Installation Guide Part ID:

FibeAir® 1500P FibeAir® IP-MAX FibeAir® IP-MAX2 IDU Installation Guide Part ID: BM-0127-0 Doc ID: DOC-00016217 Rev a.03 October 2008 Notice This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind. Registered TradeMarks Ceragon Networks® , FibeAir® and CeraView® are registered trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders. TradeMarks CeraMapTM, ConfigAirTM, PolyViewTM, EncryptAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders. Statement of Conditions The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it. Information to User Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment. Copyright © 2008 by Ceragon Networks Ltd. All rights reserved. Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: info@ceragon.com www.ceragon.com European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: infoeuro@ceragon.com North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: infous@ceragon.com APAC Headquarters: Ceragon Networks APAC (S'pore) Pte Ltd 100 Beach Road #27-01/03 Shaw Towers Singapore 189702 Tel.: 65 65724170 Fax: 65 65724199 Contents Chapter 1: Installation................................................................................... 1-1 General................................................................................................................................ 1-1 Site Requirements.............................................................................................................. 1-1 Pre-Installation ................................................................................................................... 1-1 Unpacking Equipment at the Site..................................................................................... 1-2 Installation Requirements ................................................................................................. 1-2 FibeAir 1500P Description ................................................................................................ 1-4 FibeAir IP-MAX Description .............................................................................................. 1-7 FibeAir IP-MAX2 Description............................................................................................. 1-8 Installing the IDU in a Rack............................................................................................... 1-9 Grounding the IDU ........................................................................................................... 1-11 Connecting the IDU.......................................................................................................... 1-13 Chapter 2: Initial System Setup.................................................................... 2-1 General................................................................................................................................ 2-1 Initial Setup using the Craft Terminal .............................................................................. 2-2 Additional Setup using CeraView..................................................................................... 2-5 Connecting Line Interfaces............................................................................................. 2-12 Chapter 3: Acceptance and Commissioning Procedures.......................... 3-1 General................................................................................................................................ 3-1 Site Acceptance Procedure .............................................................................................. 3-2 1+0 Commissioning Procedure ........................................................................................ 3-7 1+1 Commissioning Procedure ........................................................................................ 3-9 2+0 XPIC Commissioning Procedure............................................................................. 3-12 FibeAir 1500P/IP-MAX/IP-MAX2 Commissioning Log................................................... 3-15 Appendix A: Line Interfaces and Cables .....................................................A-1 Appendix B: Connector Pin-Outs.................................................................B-1 Appendix C: Protection Kits.........................................................................C-1 Appendix D PPP/SLIP Driver Installation ....................................................D-1 Safety Precautions & Declared Material Fiber Optic Line Precautions Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter. Do not attempt to adjust the laser drive current. Do not use broken or non-terminated fiber optic cables/connectors or look straight at the laser beam. ATTENTION: The laser beam is invisible! The use of optical devices with the equipment will increase eye hazard. CLASS 1 LASER PRODUCT Complies with IEC 60 825-1:1993 + A1:1997 + A2:2001, and EN 60825-1:1994 + A1:1996 + A2:2001 General Equipment Precautions Use of controls, adjustments, or performing procedures other than those specified herein, may result in hazardous radiation exposure. When working with a FibeAir IDU, note the following risk of electric shock and energy hazard: Diconnecting one power supply disconnects only one power supply module. To isolate the unit completely, disconnect all power supplies. Machine noise information order - 3. GPSGV, the highest sound pressure level amounts to 70 dB (A) or less, in accordance with ISO EN 7779. Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäss EN ISO 7779. Bruit de machine d’ordre - 3. GPSGV, le plus haut niveau de pression sonore s'élève à 70 dB (A) au maximum, dans le respect de la norme ISO EN 7779. ! ! ! ! ! ! ! Safety Precautions & Declared Material (continued) Static electricity may cause body harm, as well as harm to electronic components inside the device. Anyone responsible for the installation or maintainance of the FibeAir IDU must use an ESD Wrist Strap. ESD protection measures must be observed when touching the IDU. To prevent damage, before touching components inside the device, all electrostatic must be discharged from both personnel and tools. RoHS Compliance Declaration 电子信息产品有毒有害物质申明 Electronic Information Products Declaration of Hazardous/Toxic Substances 危害物质 Hazardous Substance 成分名称 Component 铅 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr VI) 多溴联苯 Polybrominated Biphenyls (PBB) 多溴二苯醚 Polybrominated Diphenyl Ethers (PBDE) 单板 / 电路模块 PCB/Circuit Modules Comply Comply Comply Comply Comply Comply 结构件 Mechanical Parts Comply Comply Comply Comply Comply Comply 电缆 Cables Comply Comply Comply Comply Comply Comply FibeAir® 1500P/IP-MAX/IP-MAX2 Installation Guide 1-1 Chapter 1: Installation General This chapter provides instructions for the installation of the FibeAir 1500P/IP-MAX/IP-MAX2 IDU at the customer site. Site Requirements Must be located indoors. The environment temperature must be between -5 C and +45 C. Easily accessible, but only by authorized personnel. Available power source of -48 VDC, and the site must comply with National Electric Code (NEC) standards. Available management connection (Ethernet or dial-up). No more than 300 m from ODU location. In addition, since the IDU will be connected to the ODU, when considering a site, it is important to check for current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings, window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be accessible to certified personnel only. Note about Antenna Location: As with any type of construction, a local permit may be required before installing an antenna. It is the owner’s responsibility to obtain any and all permits. Pre-Installation Packing The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted. Transportation y The equipment is prepared for public transportation. The cargo must be kept dry during transportation, in accordance with ETS 300 019-1-2, Class 2.3. y It is recommended to transport the equipment to the installation site in its original packing case. y If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2. FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-2 Inspection Check the packing lists, and ensure that the correct part numbers and quantities of components arrived. Unpacking Equipment at the Site A single FibeAir system (1+0) is shipped in 5 crates. Upon delivery, make sure that the following items are included: Two indoor units and accessories Two outdoor units One CD with CeraView management software (if ordered) and a CeraView user guide. Unpack the contents and check for damaged or missing parts. If any part is damaged or missing, contact your local distributor. Installation Requirements Required Tools The following tools are required to install the IDU: Philips screwdriver (for mounting the IDU to the rack and grounding screw) Flathead small screwdriver (for PSU connector and to unlock the IDC/IDMs from the chassis) Sharp cutting knife (for wire stripping) Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used). Cables In addition to the tools mentioned above, the cables necessary for IDU installation, and their pin-outs, can be found in the following sections in this guide: Appendix A: Line Interfaces and Cables Appendix B: Connector Pin-Outs FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-3 Requirements for North America Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area. Installation Codes: The equipment must be installed according to country national electrical codes. For North America, equipment must be installed in accordance to the US National Electrical Code, Articles 110- 16, 110-17 and 110-18, and the Canadian Electrical Code, Section 12. Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 15 A, must be incorporated in the building wiring. CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the earthing conductor at the equipment. Grounded Supply System: The equipment shall be connected to a properly grounded supply system. All equipment in the immediate vicinity shall be grounded the same way, and shall not be grounded elsewhere. Local Supply System: The DC supply system is to be local, i.e. within the same premises as the equipment. Disconnect Device: A disconnect device is not allowed in the grounded circuit between the DC supply source and the frame/grounded circuit connection. FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-4 FibeAir 1500P Description FibeAir 1500P is Ceragon’s modular ultra high capacity network connectivity solution designed to meet growing market demands for increased spectral-efficient systems. FibeAir 1500P is designed to deliver double the capacity using a single 28 MHz channel. In addition, the system is modular, easy to install, and a cost-effective alternative to fiber. With FibeAir 1500P operating in co-channel dual polarization (CCDP) mode, using the cross polarization interference canceller (XPIC) algorithm, two STM-1 signals uploads/s3/ ceragon-1500p-guide.pdf

  • 51
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager