01 TECHNICAL INFOAMATIONS CHOOSING CABLE 1) Voltage 1.1- Definition The nominal

01 TECHNICAL INFOAMATIONS CHOOSING CABLE 1) Voltage 1.1- Definition The nominal voltage of a conduc- tor or a cable is the voltage for which it has been aimed. It is expressed in volts or kV with in form of Uo / U.knowing that : Uo = is the effective value between the core of an insulated conductor and earth. U = is the effective value between the cores of two phase conductors. 1.2- Low voltage (LV) : The nominal voltage of the cable must be equal at least to the nominal voltage of the installation : - 300/300 V corresponding to cables reference 03. - 300/500 V corresponding to cables reference 05. - 450/750 V corresponding to cables reference 07 - 06/1 kV corresponding to cables reference 1. 1.3- Medium voltage : The specified voltage, for which the cable is conceived, is expressed by three values in kV which are Uo/U (Um) knowing that : RENSEIGNEMENTS TECHNIQUES CHOIX D’UN CABLE 1) Tension 1.1. Définition : La tension nominale d’un conducteur ou d’un cable est la tension pour laquel- le il est prévu. Elle est exprimée en volts ou kV sous la forme Uo / U avec : Uo = est la valeur efficace entre l’âme d’un conducteur isolé et la terre. U = est la valeur efficace entre les âmes conductrices de deux conducteurs de phase. 1.2- Basse tension (BT) : La tension nominale du câble doit être au moins égale à la tension nomi- nale de l’installation : -300/300 V correspondant aux câbles de référence 03. - 300/500 V correspondant aux câbles de référence 05 - 450/750 V correspondant aux câbles de référence 07. - 0.6/1 kV correspondant aux câbles de référence 1. 1.3 - Moyenne tension : La tension spécifiée, pour laquelle un câble est conçu, s’exprime par un ensemble 02 Chute de tension en V/A/km Câbles basse tension isolés PE ou PVC (Température maxi : 70°C) 3 et 4 conducteurs Voltage drop in V/A/km Low voltage cables insulated with PE or PVC (Max temperature : 70°C) 3 and 4 conductors Cuivre Copper Aluminium Aluminium Cos ϕ Section Cross-section (mm2) Cos ϕ 1.0 0.9 0.8 0.6 25.1 22.7 20.2 15.3 1.5 15.2 13.7 12.3 9.3 2.5 9.5 8.6 7.8 5.8 4 6.4 5.8 5.3 4.0 6 3.8 3.5 3.2 2.4 10 2.4 2.2 2.0 1.6 16 1.5 1.4 1.3 1.04 25 1.1 1.06 0.97 0.80 35 0.8 0.8 0.74 0.62 50 0.56 0.57 0.55 0.46 70 0.40 0.43 0.42 0.37 95 0.33 0.37 0.36 0.32 120 0.26 0.30 0.30 0.28 150 0.21 0.26 0.27 0.25 185 0.17 0.22 0.23 0.22 240 0.13 0.19 0.20 0.21 300 1.0 0.9 0.8 0.6 4.0 3.7 3.3 2.5 2.5 2.2 2.1 1.6 1.8 1.7 1.5 1.2 1.3 1.3 1.2 0.94 0.92 0.9 0.83 0.68 0.67 0.67 0.63 0.53 0.55 0.56 0.53 0.46 0.43 0.45 0.44 0.38 0.34 0.38 0.37 0.33 0.26 0.31 0.30 0.28 0.21 0.26 0.27 0.26 Ci-dessous,la section (Sc) correspon- dante. The corresponding cross section (Sc) is looked up in the tables below. 03 Chute de tension en V/A/km Câbles basse tension isolés PE ou PR (Température maxi : 85°C) 3 et 4 conducteurs Voltage drop in V/A/km Low voltage cables insulated with PE or XLPE (Max temperature : 85°C) 3 and 4 conductors Cuivre Copper Aluminium Aluminium Cos ϕ Section Cross-section (mm2) Cos ϕ 1.0 0.9 0.8 0.6 26.0 24.2 21.5 16.2 1.5 15.5 14.4 12.8 9.6 2.5 10 9 8 6.1 4 6.6 6.1 5.4 4.2 6 3.9 3.6 3.2 2.5 10 2.5 2.3 2.1 1.5 16 1.6 1.5 1.35 1.10 25 1.15 1.1 1.0 0.85 35 0.85 0.8 0.75 0.65 50 0.57 0.6 0.55 0.50 70 0.42 0.45 0.42 0.40 95 0.33 0.35 0.35 0.34 120 0.27 0.30 0.30 0.31 150 0.22 0.25 0.25 0.24 185 0.17 0.20 0.21 0.23 240 0.14 0.17 0.20 0.21 300 1.0 0.9 0.8 0.6 4.1 3.75 3.4 2.7 6.1 5.9 5.3 4.6 2.6 2.40 2.2 1.75 1.9 1.75 1.6 1.3 1.35 1.30 1.22 0.9 0.95 0.92 0.85 0.85 0.68 0.68 0.65 0.55 0.54 0.55 0.52 0.50 0.43 0.45 0.43 0.42 0.35 0.40 0.36 0.33 0.27 0.30 0.29 0.28 0.22 0.25 0.26 0.27 En cas d’utilisation du courant mono- phasé, ces valeurs doivent être multipliées par 1,154. In case of use of single phase current, these values should be multiplied by 1,154. 04 0,5 0,8 0,75 0,98 1 1,13 1,5 1,38 2,5 1,78 4 2,25 6 2,76 36 - 24,5 - 18,1 - 12,10 18,10 7,41 12,10 4,61 7,41 3,08 4,61 Section nominale Nominal cross section (mm2) Diamètre approximatif de l’âme circulaire Approximate diameter of the circular core (mm) Résistance linéique maximale de l’âme à 20°C Maximum lineic resistance of the core at 20°C (Ω/ km) Ame cuivre nu de section circulaire Bare copper core with circular cross section Ame Aluminium de section circulaire Aluminium core with circular cross section Seuls sont garantis la résistance linéique maximale et le nombre mini de brins, qui sont fixés par la norme CEI 60 228. Only the max. lineic resistance and the min. number of wires are guaran- teed, which are fixed by the standard IEC 60 228. MATERIAUX UTILISES EN CABLERIE MATERIAL USED FOR CABLES 1) Métaux Les métaux utilisés dans les câbles électriques sont : - Le cuivre électrolytique utilisé pour : * cuivre recuit nu * cuivre recuit étamé * cuivre dur - L’aluminium 3/4 dur - L’alliage d’aluminium de magné- sium et de silicium (ALMELEC) - L’acier sous forme de feuillard ou fils pour la protection mécanique des câbles. 1) Metals The metals used for electric cables are : - The electrolytic copper used for : * Annealing bare copper * Annealing tinned copper * Hard copper - 3/4 hard aluminium - The alloy of aluminium, magnesium and silicium (ALMELEC) - The steel in form of tapes or wires for mechanical protection of the cables. 1.2 - Caractéristiques des âmes : CLASSE 1 (Ame massive) 1.2 - Cores characteristics : CLASS 1 (Massive core) 05 Ame circulaire non rétreinte Non compacted circular core Ame circulaire rétreinte Compacted circular core Ame sectorale Sectoral core Résistance linéique maxi. de l’âme à 20°C Maxi lineic. resistance of core at 20°C Section nominale nominal cross section (mm2) Nombre minimal de brins Min.number of wires Diamètre Diametre (mm) Nombre minimal de brins Min. number of wires Diamètre Diametre (mm) Nombre minimal de brins Min. number of wires (Ohm/km) 0,5 0,75 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Cu Al 7 7 7 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 61 61 91 7 7 7 7 7 7 19 19 19 37 37 37 61 61 61 61 91 Approx. 0,9 1,12 1,29 1,50 2,01 2,55 3,12 4,05 5,10 6,42 7,56 8,9 10,7 12,6 14,3 15,8 17,7 20,3 22,7 25,7 28,8 31,5 6 6 6 6 6 6 6 6 6 12 15 18 18 30 34 34 53 53 53 6 6 6 6 12 15 15 15 30 30 30 53 53 53 4,6 5,6 6,6 7,7 9,3 11 12,5 13,9 15,5 17,8 20 22,9 25,7 29,3 5,2 6,5 7,5 8,6 10,2 12 13,5 15 16,8 19,2 21,6 24,6 27,6 31,5 Cu Al Mini. Maxi. Cu Al 6 6 6 6 6 6 12 12 15 15 18 18 30 34 34 53 15 15 30 30 30 53 Cu Al 36 24,5 18,1 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366 0,0283 1,20 0,868 0,641 0,443 0,320 0,253 0,206 0,164 0,125 0,100 0,0788 0,0605 0,0469 CLASSE 2 (Ame câblée rigide) CLASS 2 (Rigid stranded core) Seuls sont garantis la résistance linéique maximale et le nombre mini de brins, qui sont fixés par la norme CEI 60 228. Only the max. lineic resistance and the min. number of wires are guaran- teed, which are fixed by the standard IEC 60 228. 1,91 06 CLASSE 5 (Ame souple) CLASS 5 (Flexible core) Section nominale nominal cross section Diamètre maxi. des brins de l’âme Max. diameter of the core wires Diamètre approxi- matif de l’âme Approximate dia- meter of the core Résistance linéique maximale de l’âme à 20° C Maximum lineic resistance of core at 20°C Ame cuivre étamé Tinned copper core Ame cuivre nu Bare copper core mm2 mm mm Ohm/km Ohm/km 0,5 0,21 0,9 40,1 39,0 0,75 0,21 1,1 26,7 26,0 1 0,21 1,3 20,0 19,5 1,5 0,26 1,6 13,7 13,3 2,5 0,26 2,0 8,21 7,98 4 0,31 2,6 5,09 4,95 6 0,31 3,1 3,39 3,30 10 0,41 4,1 1,95 1,91 16 0,41 5,6 1,24 1,21 25 0,41 7,0 0,795 0,780 35 0,41 8,3 0,565 0,554 50 0,41 9,9 0,393 0,386 70 0,51 11,6 0,277 0,272 95 0,51 13,6 0,210 0,206 120 0,51 15,5 0,164 0,161 150 0,51 17,3 0,132 0,129 185 0,51 19,1 0,108 0,106 240 0,51 21,8 0,0817 0,0801 300 0,51 24,4 0,0654 0,0641 400 0,51 28,0 0,0495 0,0486 500 uploads/s3/ information-techniques.pdf

  • 16
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager