MAXIMUM VOLUME OF ENCLOSURE THAT CAN BE PROTECTED BY THE 3.0 LB. SSP 1230 SYSTE

MAXIMUM VOLUME OF ENCLOSURE THAT CAN BE PROTECTED BY THE 3.0 LB. SSP 1230 SYSTEM MAXIMUM VOLUME OF ENCLOSURE THAT CAN BE PROTECTED BY THE 7.0 LB. SSP 1230 SYSTEM MAXIMUM VOLUME OF ENCLOSURE THAT CAN BE PROTECTED BY THE 14.0 LB SSP 1230 SYSTEM Table 4 - Maximum Volume Enclosure for 3 lb. System Minimum enclosure temp Maximum hazard volume ( ft3 ) Design concentration number 3 4 5 6 7 8 9 10 0 95.8 71.1 56.3 46.4 39.4 34.1 30.0 26.7 10° 98.0 72.7 57.6 47.5 40.3 34.8 30.6 27.3 20° 100.3 74.5 59.0 48.6 41.2 35.7 31.4 27.9 30° 102.7 76.2 60.4 49.8 42.2 36.5 32.1 28.6 40° 105.1 78.0 61.7 50.9 43.2 37.4 32.9 29.2 50° 107.4 79.8 63.1 52.1 44.1 38.2 33.6 29.9 60° 109.8 81.5 64.5 53.2 45.1 39.1 34.3 30.6 70° 112.2 83.3 65.9 54.4 46.1 39.9 35.1 31.2 80° 114.5 85.0 67.3 55.5 47.1 40.7 35.8 31.9 90° 116.9 86.8 68.7 56.6 48.0 41.6 36.6 32.5 100° 119.3 88.5 70.1 57.8 49.0 42.4 37.3 33.2 110° 121.6 90.3 71.5 58.9 50.0 43.3 38.0 33.9 120° 124.0 92.1 72.9 60.1 51.0 44.1 38.8 34.5 130° 126.4 93.8 74.3 61.2 51.9 45.0 39.5 35.2 Table 5 - Maximum Volume Enclosure for 7 lb. System Minimum enclosure temp Maximum hazard volume ( ft3 ) Design concentration number 3 4 5 6 7 8 9 10 0 223.6 166.0 131.4 108.4 91.9 79.5 69.9 62.2 10° 228.6 169.7 134.3 110.8 93.9 81.3 71.5 63.6 20° 234.1 173.8 137.6 113.4 96.2 83.3 73.2 65.2 30° 239.6 177.9 140.8 116.1 98.5 85.2 74.9 66.7 40° 245.2 182.0 144.1 118.8 100.7 87.2 76.7 68.2 50° 250.7 186.1 147.3 121.5 103.0 89.2 78.4 69.8 60° 256.2 190.2 150.6 124.1 105.3 91.1 80.1 71.3 70° 261.7 194.3 153.8 126.8 107.6 93.1 81.9 72.9 80° 267.3 198.4 157.1 129.5 109.8 95.1 83.6 74.4 90° 272.8 202.5 160.3 132.2 112.1 97.0 85.3 75.9 100° 278.3 206.6 163.6 134.9 114.4 99.0 87.0 77.5 110° 283.8 210.7 166.8 137.5 116.6 101.0 88.8 79.0 120° 289.4 214.8 170.0 140.2 118.9 102.9 90.5 80.5 130° 294.9 218.9 173.3 142.9 121.2 104.9 92.2 82.1 Table 6 - Maximum Volume Enclosure for 14 lb. System Minimum enclosure temp Maximum hazard volume ( ft3 ) Design concentration number 3 4 5 6 7 8 9 10 0 447.2 332.0 262.8 216.7 183.8 159.1 139.9 124.5 10° 457.2 339.4 268.7 221.5 187.9 162.6 143.0 127.3 20° 468.2 347.6 275.2 226.9 192.4 166.5 146.4 130.3 30° 479.3 355.8 281.6 232.2 196.9 170.5 149.9 133.4 40° 490.3 364.0 288.1 237.6 201.5 174.4 153.3 136.5 50° 501.4 372.2 294.6 242.9 206.0 178.3 156.8 139.6 60° 512.4 380.4 301.1 248.3 210.6 182.3 160.2 142.6 70° 523.5 388.6 307.6 253.7 215.1 186.2 163.7 145.7 80° 534.5 396.8 314.1 259.0 219.6 190.1 167.2 148.8 90° 545.6 405.0 320.6 264.4 224.2 194.1 170.6 151.9 100° 556.6 413.2 327.1 269.7 228.7 198.0 174.1 154.9 110° 567.7 421.4 333.6 275.1 233.3 201.9 177.5 158.0 120° 578.7 429.6 340.1 280.4 237.8 205.8 181.0 161.1 130° 589.8 437.8 346.6 285.8 242.3 209.8 184.4 164.2 PRE-ENGINEERED SYSTEM CALCULATION GUIDE HOW TO DETERMINE THE CORRECT SSP 1230 SYSTEM FOR YOUR APPLICATION. Step 1 Identify the hazard to protect and note the applicable design concentration number. Example: Hazard is Class C (Energized) 4.5% 4.7% required Round up design concentration to 5% (next whole number) L = 2 ft. W = 5 ft. H = 8 ft. Electrical Control Cabinet Step 2 To identify the flooding factors number determine the enclosure’s minimum temperature and align this with the rounded up design concentration number in Table 2 left. Example: Minimum temperature is 70°F, rounding up number is 5; therefore flooding factor number is 0.0455. Step 3 Calculate cubic feet of enclosure by multiplying the width x length x height. To identify required system size multiply cubic feet of enclosure by the flooding factors number. Example: Enclosure is 5 ft. W x 2 ft. L x 8 ft. H = 80 cubic feet. 80 x 0.0455 = 3.64. This would round up to the 7 lb. system. Step 4 Use Table 3 to double check that the enclosure to be protected does not exceed the maximum area coverage of the tested nozzles and the volume coverage does not exceed the maximum hazard volume of enclosure in Table 4. Example: The enclosure is 10 ft2 and the max coverage of 7 lb nozzle is 108.10 ft2. The 7 lb system can protect up to 153.8 ft3 at 70°F with a design concentration of 5%. Table 3 - Maximum Area Coverage System Max area coverage 3 lb. 46.33 ft2 7 lb. 108.10 ft2 14 lb. 216.10 ft2 Table 2 - Flooding Factor Numbers Design concentration number 3 4 5 6 7 8 9 10 30°F 0.0292 0.0394 0.0497 0.0603 0.0711 0.0821 0.0934 0.1049 40°F 0.0286 0.0385 0.0486 0.0589 0.0695 0.0803 0.0913 0.1026 50°F 0.0279 0.0376 0.0475 0.0576 0.0680 0.0785 0.0893 0.1003 60°F 0.0273 0.0368 0.0465 0.0564 0.0665 0.0768 0.0874 0.0981 70°F 0.0267 0.0360 0.0455 0.0552 0.0651 0.0752 0.0855 0.0961 80°F 0.0262 0.0353 0.0446 0.0541 0.0637 0.0736 0.0838 0.0941 90°F 0.0257 0.0346 0.0437 0.0530 0.0624 0.0721 0.0821 0.0922 100°F 0.0252 0.0339 0.0428 0.0519 0.0612 0.0707 0.0804 0.0904 110°F 0.0247 0.0332 0.0420 0.0509 0.0600 0.0693 0.0789 0.0886 120°F 0.0242 0.0326 0.0412 0.0499 0.0589 0.0680 0.0774 0.0869 130°F 0.0237 0.0320 0.0404 0.0490 0.0578 0.0667 0.0759 0.0853 Table 1 - Hazards to Protect Flammable Liquid Design Concen- tration % v/v Flammable Liquid Design Concen- tration % v/v 1-Butane 6.37 lsooctane 6.11 1-Propanol 7.02 Isopropanol Alcohol 6.37 2,2,4- trimethylpentane 6.11 Methane 7.28 2-butoxyethanol 6.76 Methanol 8.45 Acetone 5.59 Methyl Ethyl Ketone 5.85 Acetonitrile 4.20 Methyl Isobutyl Ketone 5.72 Commercial Heptane 5.72 Methyl T ert Butyl Ether 5.95 Commercial Hexanes 5.59 n-Heptane 5.85 Cyclohexane 5.85 n-Heptane 6.11 Cyclopentanone 5.98 Octane 5.72 Denatured Alcohol (92.2% EtOH, 4.6% IPA, and 3.1% MeOH) 6.89 Propane 7.54 Diesel Fuel 4.42 Pyrrolidine 6.11 Diethl Ether 6.37 T echnical Heptane 5.59 Ethanol 7.15 Tetrahydrofuran 6.50 Ethyl Acetate 6.11 Toluene 4.55 Gasoline-87 oct. unleaded 5.85 Transformer Oil 5.85 Hexene 5.98 Class A & de-energized Class C Fires 4.20 * Note: Design Concentration for Class B Fire are shown in the above table and includes a 30% safety factor from the minimum extinguishing concentration. uploads/Geographie/ calculation-guide.pdf

  • 36
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager