ii Table des matières CHAPITRE 1 : LES APPAREILLAGES ELECTRIQUES_______________
ii Table des matières CHAPITRE 1 : LES APPAREILLAGES ELECTRIQUES_________________________________ 1 I. INTRODUCTION_____________________________________________________________________ 2 1. FONCTION SECTIONNEMENT_______________________________________________________________ 2 2. FONCTION COMMANDE___________________________________________________________________ 2 3. FONCTION PROTECTION __________________________________________________________________ 2 II. LES APPAREILS DE SECTIONNEMENT________________________________________________ 3 1. SECTIONNEUR _________________________________________________________________________ 3 1.1. Sectionneur porte fusible ____________________________________________________________ 3 1.2. Interrupteur sectionneur_____________________________________________________________ 4 III. LES APPAREILS DE PROTECTION ____________________________________________________ 4 1. LE FUSIBLE____________________________________________________________________________ 5 2. DECLENCHEUR (RELAIS) _________________________________________________________________ 7 IV. LES APPAREILS DE COMMANDE ET DE PROTECTION_________________________________ 7 1. CONTACTEUR MAGNETIQUE_______________________________________________________________ 7 2. DISCONTACTEUR _______________________________________________________________________ 8 3. DISJONCTEUR__________________________________________________________________________ 8 3.1. Disjoncteur thermique ______________________________________________________________ 8 3.2. Disjoncteur magnétique _____________________________________________________________ 9 3.3. Disjoncteur magnétothermique ______________________________________________________ 12 3.4. Les normes de différentes courbes____________________________________________________ 13 3.5. Pouvoir de coupure et de fermeture___________________________________________________ 14 3.6. Disjoncteur et interrupteur différentiels________________________________________________ 15 4. LES APPAREILS DE COMMANDE MANUELLE __________________________________________________ 16 4.1. Interrupteur _____________________________________________________________________ 16 4.2. Commutateur ____________________________________________________________________ 16 4.3. Bouton poussoir et boite à BP _______________________________________________________ 17 5. LES APPAREILS DE COMMANDE AUTOMATIQUE _______________________________________________ 17 5.1. Les Contacts auxiliaires ____________________________________________________________ 17 5.2. Les Contacts auxiliaires temporisés___________________________________________________ 18 5.3. Le relais auxiliaire à contacts instantanés ______________________________________________ 18 5.4. Le relais auxiliaire à contacts temporisés_______________________________________________ 18 V. SIGNALISATIONS___________________________________________________________________ 19 VI. COFFRET ELECTRIQUE ____________________________________________________________ 19 1. REPERAGE DES CONDUCTEURS ET DE MATERIELS _____________________________________________ 20 2. REPERAGE EQUIPOTENTIEL ______________________________________________________________ 20 CHAPITRE 2: SCHEMAS NORMES ET INSTALLATIONS DOMESTIQUES ____________ 21 I. DEFINITIONS_______________________________________________________________________ 22 II. CLASSIFICATIONS DES SCHEMAS___________________________________________________ 22 1. LES SCHEMAS EXPLICATIFS ______________________________________________________________ 22 2. DIAGRAMMES OU TABLEAUX EXPLICATIFS __________________________________________________ 22 3. LES SCHEMAS DE REALISATIONS OU TABLEAUX DE CONNEXIONS _________________________________ 23 4. LES PLANS OU TABLEAUX DE DISPOSITION___________________________________________________ 23 5. CLASSIFICATION SELON LE MODE DE REPRESENTATION _________________________________________ 23 5.1. L’emplacement des matériel ________________________________________________________ 23 5.2. L’emplacement des symboles _______________________________________________________ 23 III. ETUDE DES DIFFERENTS SCHEMAS _________________________________________________ 23 1. REPRESENTATION SUIVANT L’EMPLACEMENT DES MATERIELS____________________________________ 23 2. SUIVANT L’EMPLACEMENT DES SYMBOLES __________________________________________________ 24 2.1. Représentation développé __________________________________________________________ 24 iii IV. NORMALISATION ELECTRIQUE ____________________________________________________ 26 V. LES INSTALLATIONS ELECTRIQUES DOMESTIQUES _________________________________ 26 1. MONTAGE SIMPLE ALLUMAGE ____________________________________________________________ 26 2. MONTAGE DOUBLE ALLUMAGE ___________________________________________________________ 28 3. MONTAGE VA ET VIENT_________________________________________________________________ 30 4. MONTAGE TELERUPTEUR________________________________________________________________ 32 5. MONTAGES AVEC MINUTERIE_____________________________________________________________ 37 6. SCHEMA DEVELOPPE D’UN MONTAGE A CAGE D’ESCALIER ______________________________________ 39 7. MONTAGES AVEC TUBES FLUORESCENTS ___________________________________________________ 40 7.1. Montage tube fluorescent à allumage différé____________________________________________ 40 7.2. Montage tube fluorescent a allumage instantané _________________________________________ 40 8. MONTAGE EN DUO AVEC TUBES FLUORESCENTS______________________________________________ 41 8.1. Allumage différé par starter_________________________________________________________ 41 8.2. Allumage instantané ______________________________________________________________ 42 9. MONTAGES SONNERIES _________________________________________________________________ 42 10. ________________________________________________________ GACHE ELECTRIQUE 44 VI. LES INSTALLATIONS ELECTRIQUES INDUSTRIELLES________________________________ 46 1. NORMALISATION ______________________________________________________________________ 46 2. CHOIX D’UN DEMARREUR _______________________________________________________________ 46 3. DEMARRAGE MANUEL D’UN MAS TRIPHASE A ROTOR A CAGE ___________________________________ 46 3.1. Démarrage Manuel d’un MAS triphasé 1 Sens de Rotation ________________________________ 46 3.2. Démarrage Manuel d’un MAS triphasé 2 Sens de Rotation ________________________________ 47 4. DEMARRAGE SEMI-AUTOMATIQUE D’UN MAS TRIPHASE A ROTOR A CAGE __________________________ 48 4.1. Démarrage d’un MAS Triphasé 1 sens de rotation _______________________________________ 48 4.2. Démarrage Semi-automatique d’un MAS triphasé 2 Sens de Rotation ________________________ 49 5. DEMARRAGE SEMI-AUTOMATIQUE ETOILE TRIANGLE D’UN MAS TRIPHASE A CAGE ___________________ 50 5.1. Démarrage étoile triangle d’un MAS 1 sens de rotation ___________________________________ 50 5.2. Démarrage étoile triangle d’un MAS triphasée 2 sens de rotation____________________________ 53 6. DEMARRAGE D’UN MAS TRIPHASE PAR ELIMINATION DE RESISTANCES STATORIQUES _________________ 55 6.1. Démarrage d’un MAS triphasé 1 sens de rotation ________________________________________ 55 7. DEMARRAGE SEMI-AUTOMATIQUE D’UN MAS TRIPHASE PAR AUTOTRANSFORMATEUR ________________ 57 8. FREINAGE D’UN MAS TRIPHASE A CAGE ____________________________________________________ 60 8.1. Freinage d’un MAS triphasé par contre courant _________________________________________ 60 8.2. Freinage d’un MAS triphasé par injection de courant continu ______________________________ 61 8.3. Moteur frein_____________________________________________________________________ 62 CHAPITRE 3 : PROTECTION DES PERSONNES ET DES EQUIPEMENTS ____________ 64 I. SENSIBILITE ET TENSIONS DE SECURITE DU CORPS HUMAIN _________________________ 65 1. SENSIBILITE DU CORPS HUMAIN ___________________________________________________________ 65 2. TENSION LIMITE DE SECURITE ____________________________________________________________ 65 II. CONTACTS DIRECT ET INDIRECT___________________________________________________ 67 1. CONTACTS DIRECT ET INDIRECT___________________________________________________________ 67 2. PROTECTION CONTRE LES CONTACTS DIRECTS________________________________________________ 67 3. PROTECTION CONTRE LES CONTACTS INDIRECTS ______________________________________________ 68 4. MESURE DE PROTECTION SANS COUPURE DE L'ALIMENTATION ___________________________________ 68 4.1. Utilisation de la TBTS _____________________________________________________________ 68 4.2. Utilisation de la TBTP _____________________________________________________________ 69 III. REGIMES DE NEUTRES _____________________________________________________________ 69 1. REGIME DE NEUTRE DE TYPE TT __________________________________________________________ 70 2. REGIME DE NEUTRE DE TYPE TN __________________________________________________________ 72 3. REGIME DE NEUTRE DE TYPE IT ___________________________________________________________ 75 BIBLIOGRAPHIE _____________________________________________________________________ 81 LOGICIELS UTILISES_________________________________________________________________ 81 ANNEXES ____________________________________________________________________________ 82 Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 1 Proposé par Mr: SOYED-Abdessamï Chapitre 1 : Les appareillages électriques Objectifs : Comprendre les fonctions de sectionnement, de commande et de protection, Choisir et dimensionner les appareillages électriques convenables pour une installation électrique. Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 2 Proposé par Mr: SOYED-Abdessamï I. Introduction La réglementation définit trois fonctions de base pour les appareillages dans la conception d’une installation électrique. 1. Fonction sectionnement Les sectionneurs ont pour but d’ouvrir visiblement en un point quelconque une installation électrique sans charges. 2. Fonction commande Il existe deux types de commande : La commande fonctionnelle et la commande de sécurité. La commande fonctionnelle (service normal) assure la mise en « ON » ou « OFF » d’un système électrique. La commande de sécurité (arrêt d’urgence) assure la mise en « OFF » d’un système électrique lors d’un danger pour les biens ou les personnes. 3. Fonction protection Elle permet de limiter les conséquences destructives ou dangereuses des surintensités ou des défauts d’isolement et de séparer la partie défectueuse du reste de l’installation. L’appareil de protection doit laisser en permanence le courant nominal (In), ainsi que les surintensités normales. Elle doit réaliser la coupure de sécurité et participer à la protection des personnes contre les contacts indirects. On distingue 3 types de surintensités ( s n I =λ.I ): La surcharge faible (1<λ<2 ), on utilise des dispositifs thermiques pour leurs protections. La surcharge forte ( 2<λ<10), on utilise des dispositifs magnétiques pour leurs protections. Les courts-circuits (λ>10), on utilise des fusibles et dispositifs magnétiques pour leurs protections. Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 3 Proposé par Mr: SOYED-Abdessamï II. Les appareils de sectionnement 1. Sectionneur C’est un appareil qui permet de séparer (isoler) une partie sous tension en amont d’une partie en aval d’un circuit électrique. L’isolement du circuit se fait à vide par ouverture de tous les conducteurs de lignes (mais pas le conducteur PE). Le sectionneur ne possède pas des pouvoirs de coupure et fermeture. Le verrouillage se fait par un cadenas. Fig.1.1: Sectionneurs Triphasé 1.1. Sectionneur porte fusible Il permet d’isoler et protéger la partie amont sous tension de la partie aval d’un circuit électrique. Fig.1.2: Sectionneurs triphasés porte fusible Critères de choix d’un sectionneur porte fusible: Calibre et aille. Classe de protection et tension d’emploi, Nombre de pôles. Sectionneur triphasé à commande manuelle Sectionneur à levier 3Ph+N avec contact auxiliaire Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 4 Proposé par Mr: SOYED-Abdessamï 1.2. Interrupteur sectionneur Il permet de séparer et d’interrompre (ouvrir ou fermer) manuellement un circuit en charge. Il possède un pouvoir de coupure (Pdc). Fig.1.3: Interrupteurs-Sectionneurs triphasés Choix d’interrupteur sectionneur: Courant et tension d'emploi, Pouvoir de coupure (Pdc): Courant de coupure, Nombre de pôles (tripolaire, bipolaire..). III. Les appareils de protection Les appareils de protection déclenchent en cas des anomalies (surcharges, surintensité, etc.…). Fig.1.4: Déclenchement d’un appareil de protection u I n I f I cc I I min I max I n utilisatio d' Courant Courant de surcharge Courant de court-circuit nominal Courant ment) (déclenche fusion de Courant ) (P coupure de Pouvoir dc 0 Interrupteur-Sectionneur Interrupteur Interrupteur-Sectionneur à fusibles Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 5 Proposé par Mr: SOYED-Abdessamï Caractéristiques: Courant d’utilisation: Iu, Courant nominal:In, Surintensité : Démarrage moteur, Surcharge: Echauffement thermique, Pouvoir de coupure: Courant maximal qu'un dispositif de protection peut couper un circuit Pdc (kA). 1. Le fusible Il protège un circuit électrique contre les courts-circuits par fusion da la partie active du fusible. Il comporte de poutre de silice pour étouffer rapidement l’arc électrique et assurer l’isolement après la coupure. Il existe plusieurs types de fusible. Fig.1.5: Symbole d’un fusible Types : Les cartouches gG (usage industriel) protègent les circuits électriques contre les faibles et fortes surcharges et contre les courts-circuits. Les cartouches aM (Accompagnement Moteur) protègent les circuits électriques contre les fortes surcharges et les courts-circuits. Les cartouches UR (Ultra Rapide) protègent les composants électroniques. Caractéristiques: Tension et courant nominaux: Un, In Courant de non fusion Inf: Courant supporté par le fusible pendant un temps spécifié sans fondre. Courant de fusion If: Courant qui provoque la fusion avant la fin d'un temps spécifié. Chapitre 1 : Les Appareillages Electriques Cours Electricité Industrielle 6 Proposé par Mr: SOYED-Abdessamï Courbes temps de fusion: La courbe de fusion est la caractéristique donnant le temps de fusion en fonction de courant traversant la cartouche. Fig.1.10: Courbes temps de fusion Calibres uploads/Industriel/ appareillage-electrique.pdf
Documents similaires
-
13
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Attribution requise- Détails
- Publié le Jan 24, 2022
- Catégorie Industry / Industr...
- Langue French
- Taille du fichier 2.8762MB