AIPCR VIA f~) VITA PIARC 2007 SYSTÈMES ET ÉQUIPEMENTS POUR LA MAÎTRISE DES INCE

AIPCR VIA f~) VITA PIARC 2007 SYSTÈMES ET ÉQUIPEMENTS POUR LA MAÎTRISE DES INCENDIES ET DES FUMÉES DANS LES TUNNELS ROUTIERS Comité AIPCR de l'Exploitation des Tunnels routiers (C3.3) PIARC Committee on Road Tunnels Operation (C3.3) SYSTÈMES ET ÉQUIPEMENTS POUR LA MAÎTRISE DES INCENDIES ET DES FUMÉES DANS LES TUNNELS ROUTIERS SYSTEMS AND EQUIPMENT FOR FIRE AND SMOKE CONTROL IN ROAD TUNNELS SOMMAIRE ISBN: 2-84060-175-3 PREAMBULE 10 INTRODUCTION 14 1 PRINCIPES DE BASE DE LA PROGRESSION DES FUMEES ET DE LA CHALEUR AU DEBUT D'UN INCENDIE 22 1.1 INTRODUCTION 22 1.2 INFLUENCE DE LA VITESSE LONGITUDINALE DE L'AIR 24 1.3 INFLUENCE DE LA PUISSANCE THERMIQUE 26 1.4 INFLUENCE DE LA PENTE DU TUNNEL (DECLIVITE DE LA CHAUSSEE) 26 1.5 INFLUENCE DU TRAFIC 26 1.6 ROLE DU SYSTEME DE VENTILATION PENDANT LA PHASE D·AUTO-EVACUATION 28 1.7 ROLE DU SYSTEME DE VENTILATION PENDANT LA PHASE DE DECLENCHEMENT DE L'INCENDIE 28 2 CONCEPTS DE SECURITE POUR LES INCENDIES EN TUNNEL 30 2.1 INTRODUCTION 30 2.2 TRAVAUXANTERIEURS DE L·AIPCR 32 2.3 SECURITE INCENDIE EN TUNNEL 32 2.3.1 Objectifs de la sécurité incendie en tunnel 34 2.3.2 Remarques sur les accidents en tunnel 36 2.3.3 Sécurité pendant les phases de projet, de construction. d'exploitation et d'entretien 36 2.3.4 Plans d'intervention ä'urqence 46 2.3.5 Risques et analyse des risques 46 2.4 LE CONCEPT DE SECURITE 48 3 ENSEIGNEMENTS TIRES DES INCENDIES RECENTS EN TUNNEL 54 3.1 INTRODUCTION 54 3.2 DESCRIPTION DES TUNNELS DU MONT-SLANC, DES TAUERN ET DU ST. GOTHARD 56 3.2.1 Géométrie 56 3.2.2 Trafic 60 3.2.3 Capacités de ventilation 60 3.2.4 Instaflations de sécurité dans les tunnels 64 3.2.5 Exploitation des tunnels 66 3.3 LES INCENDIES ET LEUR GESTION 70 3.3.1 Conditions de trafic avant et après les alertes d'incendie 70 3.3.2 Les incendies 72 3.3.3 Gestion de f'incendie par les exploitants 74 3.3.4 Première intervention des équipes de secours 78 3.3.5 Environnement interne des tunnels pendant les incendies 80 3.3.6 Comportement des usagers 82 3.3.7 Conséquences des catastrophes 86 AlPCR. 2 . o5.16.B - 2006 CONTENTS FOREWORD 11 INTRODUCTION 15 1 BASIC PRINCIPlES OF SMOKE AND HEAT PROGRESS AT THE BEGINNING OF A FIRE 23 1.1 INTRODUCTION 23 1.2 INFLUENCE OF LONGITUDINAL AIR VELOCITY 25 1.3 INFLUENCE OF THE FIRE HEAT RELEASE RATE 27 1.4 INFLUENCE OF THE TUNNEL SLOPE (ROADWAY GRADE) 27 1.5 INFLUENCE OF THE TRAFFIC 27 1.6 ROLE OF THE VENTILATION SYSTEM DURING THE SELF-EvACUATION PHASE 29 1.7 ROLE OF THE VENTILATION SYSTEM DURING THE FIRE-FIGHTING PHASE 29 2 SAFETY CONCEPTS FOR TUNNEL FIRES 31 2.1 INTRODUCTION 31 2.2 PREVIOUS WORK BY PIARC 33 2.3 TUNNEL FIRE SAFETY 33 2.3.1 Aims of Tunnel Fire Safety 35 2.3.2 Remarks on Tunnel Accidents 37 2.3.3 Safety during Design, Construction, Operation and Maintenance Phases 37 2.3.4 Emergency Planning .47 2.3.5 Risk and Risk Analysis .47 2.4 THE SAFETY CONCEPT .49 3 LESSONS lEARNED FROM RECENT TUNNEL FIRES 55 3.1 INTRODUCTION .........................................................................•.................... 55 3.2 DESCRIPTION OF THE MONT BLANC, TAUERN AND ST. GOTIHARD TUNNELS 57 3.2.1 Geometry 57 3.2.2 Traffic 61 3.2.3 Ventilation Capacities 61 3.2.4 Safety Facilities in the Tunnels 65 3.2.5 Tunnel Operation 67 3.3 THE FIRES AND THEIR MANAGEMENT 71 3.3.1 Traffic Conditions Before and After the Fire Alarms 71 3.3.2 The Fires 73 3.3.3 Fire Management by the Operators 75 3.3.4 First Response by Rescue Teams 79 3.3.5 Environment in the Tunnels during the Fires 81 3.3.6 Users' Behaviour 83 3.3.7 Results ofthe Catastrophes 87 PIARC • 3 . 05,16,8·2006 3.4 PREMIERS ENSEIGNEMENTS TIRES DE CES INCENDIES 86 3.5 CONCLUSIONS 94 4 VENTILATION :96 4.1 INTRODUCTION 96 4.2 TRAVAUX ANTERIEURS DE L'AIPCR. 96 4.3 VENTILATION TRANSVERSALE 96 4.3.1 Objectifs 96 4.3.2 Règles de dimensionnement 98 4.3.3 Exigences pour la stratification des fumées 100 4.3.4 Spécifications concemant les équipements 104 4.4 VENTILATION LONGITUDINALE 106 4.4.1 Introduction 106 4.4.2 Impact sonore des accélérateurs dans un tunnel 106 4.5 ESSAIS 108 5 ISSUES DE SECOURS 110 5.1 INTRODUCTION 110 5.2 TRAVAUX ANTERIEURS DE L'AIPCR 110 5.3 DIMENSIONNEMENT DE L'ITINERAIRE D'EVACUATION 112 5.3.1 Types de confinement 114 5.3.2 Puissance et développement de I'incendie 114 5.3.3 Comportement humain 122 5.3.4 Ventilation 124 5.3.5 Pente de la chaussée (déclivité) 130 5.3.6 Contró/es en tunnel... 132 5.4 EVACUATION DE SECOURS 132 5.4.1 Issues de secours 132 5.4.2 Itinéraires d'évacuation 134 5.4.3 Abris 136 5.4.4 Accès des services de secours 136 5.5 ALARME ET GUIDAGE 140 5.6 ENQUETE SUR L'EVACUATION DE SECOURS 140 6 ÉQUIPEMENTS SPECIFIQUES POUR lES INCENDIES 142 6.1 INTRODUCTION 142 6.2 TRAVAUX ANTERIEURS DE L'AIPCR. 142 6.3 DETECTION DES INCENDIES 150 6.3.1 But des détecteurs d'incendie 150 6.3.2 Paramètres des détecteurs d'incendie 152 6.3.3 Méthodes utilisées actuellement.. 160 6.3.4 Résultats ä'esseis 172 6.4 SYSTEMES AUTOMATIQUES DE LUTTE CONTRE LE FEU 174 6.4.1 Expérience internationale actuelle 174 6.4.2 Méthodes en cours de développement... 182 6.5 CONCLUSIONS 188 AlPCR. 4.05.15.8-2006 3.4 PRIMARY LESSONS LEARNED FROM THESE FIRES .........•..........•.................•..... 87 3.5 CONCLUSIONS .....•........................................................•.•................••.••.•...... 95 4 VENTILATION 97 4.1 INTRODUCTION ...............•....................................................•......................... 97 4.2 PREVIOUS WORK BY PIARC •....................•................•..............•.................... 97 4.3 TRANSVERSE VENTILATION .....................................•...••................................. 97 4.3.1 Objectives 97 4.3.2 Dimensioning Rules 99 4.3.3 Requirements tor smoke stratitication 101 4.3.4 Equipment Specitications 105 4.4 LONGITUDINAL VENTILATION .......................................•................................. 107 4.4.1 Introduction 107 4.4.2 Sound Impact ot Jet Fans in a Tunnel 107 4.5 TESTS ......................................................................................................•• 109 5 EMERGENCY EXiTS ..................................................•.....................•............••• 111 5.1 INTRODUCTION 111 5.2 PREVIOUS WORK BY PIARC ...........................•........................................... 111 5.3 ESCAPE ROUTE DESIGN ..................................................................•........... 113 5.3.1 Types ot Enclosures , 115 5.3.2 Fire Size and Development... 115 5.3.3 Human Behaviour 123 5.3.4 Ventifation 125 5.3.5 Slope otthe Road Surface (Grade) 131 5.3.6 Tunnel Controls 133 5.4 EMERGENCY EGRESS ......................................................•........................... 133 5.4.1 Emergency Exits 133 5.4.2 Escape Routes 135 5.4.3 Shelters 137 5.4.4 Access tor Rescue Personnel 137 5.5 WARNING AND GUIDING .............•................................................................. 141 5.6 ENQUIRY PROVISIONS FOR EMERGENCY EGRESS ........•....•............................ 141 6 FIRE SPECIFIC EQUIPMENT 143 6.1 INTRODUCTION 143 6.2 PREVIOUS WORK BY PIARC 143 6.3 FIRE DETECTION 151 6.3.1 Purpose ot Fire Detectors 151 6.3.2 Fire Detector Parameters 153 6.3.3 Currently Used Methods 161 6.3.4 Test Results 173 6.4 AUTOMATIC FIRE SUPPRESSION 175 6.4.1 Current International Experience 175 6.4.2 Methods Under Development.. 183 6.5 CONCLUSIONS 189 PIARC • 5 . 05.16.8 - 2006 7 CRITERES DE CONCEPTION POUR LA RESISTANCE AU FEU DES STRUCTURES 190 7.1 INTRODUCTION ...................•..............................................••...•....•............. 190 7.2 TRAVAUXANTERIEURS DE L'AIPCR. .........................................................•.. 192 7.3 CONTEXTE 194 7.4 CRITERES DE CONCEPTION .....................................................•................•.. 196 7.4.1 Courbes température-temps 196 7.4.2 Recommandations ..............................................•....................... 198 7.5 ACTIVITES FUTURES .....................•..........•••.....•.•.•.•.•.•...•......................•..... 202 7.5.1 Introduetion descoarbes d'lncendÎe entunneldans les normes. 202 7.5.2 IngénÎerie de la sécurité ÎncendÎe ..............•................................ 202 8 RESPONSABILITES OPERATIONNELLES EN CAS D'URGENCE 204 8.1 INTRODUCTION 204 8.2 TRAVAUX ANTERIEURS DE L'AIPCR 204 8.3 MISE EN CEUVRE DES SYSTEMES DE MAITRISE DES FUMEES ...••...........••....•..... 206 8.4 ACTION DES SERVICES D'INTERVENTION 210 8.4.1 Introduction 210 8.4.2 Communicetions ..........................•.............................................. 210 8.5 PLAN - FORMATION - ExERCICE ..............•..........•..........•.•...•...........•.•.......• 214 8.5.1 Scénarios et procédures d'exploitation 214 8.5.2 Plan d'intervention d'urgence ......•............................................... 214 8.5.3 Formation. 216 8.6 ENTRETIEN PREVENTIF, INSPECTIONS ET ESSAIS ............................•..•........... 216 8.6.1 Introduetion 216 8.6.2 Equipements et systèmes de controle 218 8.6.3 Archivage exhaustif 220 8.6.4 Coûts et budgets d'entretien 220 8.7 ESSAIS DU SYSTEME DE VENTILATION ..............••...•...................................... 220 8.7.1 Organisation générale de la structure de controle 222 8.7.2 Données de base et saM des données ..........•........................... 222 8.7.3 Essais du système de ventilation 226 9 L'AVENIR 230 10 REFERENCES ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 234 11 BIBLIOGRAPHIE 242 AlPCR. 6 . 05.16.8·2006 7 DESIGN CRITERIA FOR STRUCTURE RESISTANCE TO FIRE ••..•......••.......191 7.1 INTRODUCTION ......•...............•............•............•.....................••...••...•.......•... 191 7.2 PREVIOUS WORK BY PIARC ........•..................................•..•.............•........... 193 7.3 BACKGROUND 195 7.4 DESIGN CRITERIA 197 7.4.1 Time· Temperature Curves ; 197 7.4.2 Guidelines 199 7.5 FUTURE ACTlVITIES .....................................•...........•.......•........•....•...•......... 203 7.5.1 Introductionof Tunnel Fire Curves into Standards 203 7.5.2 Fire Safety Engineering 203 8 OPERA TIONAL RESPONSIBILITIES ·FOR EMERGENCIES 205 8.1 INTRODUCTION ....................•..•.......•....•...••..•..••..•••.•.•..••..............•....•.......... 205 8.2 PREVIOUS WORK BY PIARC ......................................•................................. 205 8.3 OPERATION OF SMOKE CONTROLSYSTEMS .......................................•.......... 207 8.4 EMERGENCY SERVICE INTERVENTION 211 8.4.1 Introduction ........................................................................•.......... 211 8.4.2 Communicatlons ..............................................•...........•............... 211 8.5 PLAN - TRAINING - EXERCISE .......................•..•..•...•..••...•............•............... 215 8.5.1 OperatingScenariosandProcedures ..•..•......•....................; 215 8.5.2 Emergency Response Plan ......................•..•..........•....................... 215 8.5.3 Training ...............................•.............•.•....•..............•...................... 217 8.6 PREVENTIVE MAINTENANCE, INSPECTION AND TESTING 217 8.6.1 tntroductlon 217 8.6.2 Equipment and Controls 219 8.6.3 Comprehensive Record Keeping 221 8.6.4 Maintenance Costs and Budgets 221 8.7 VENTILATION SYSTEM TESTS 221 8.7.1 General Organisation ofthe Control Structure 223 8.7.2 Basic Data and Data Monitoring 223 8.7.3 Ventilation System Tests 227 9 THE FUTURE 231 10 REFERENCES 235 11 BIBLIOGRAPHY 243 PIARC • 7 . 05.16.8 - 2006 12 ANNEXES ...................................•....................•................................................. 246 12.1 STATISTIQUES NORVEGIENNES D'INCIDENTS ET D'ACCIDENTS 246 12.2 LA RENOVATION DU TUNNEL DU MONT-SLANC .•...........•..•...•....•.......•............ 250 12.2.1 /ntroduction 250 12.2.2 Rénovation 252 12.2.3 Dimensionnement ...........................................•........................... 252 12.2.4 Fonctlonnement automatique ....•........ ; 254 12.2.5 Essais d'incendie en grandeur réeJle 254 12.3 DIMENSIONNEMENT OESINSTAI..LATlONS DE VE;:NTILATION LONGITUDINALE;: •.....• 258 12.3.1 /ntroduction ........••~; .•.; ;.••...;.., ; c •••••••••••••••••••••• ~ •••••••••••••• 258 12.3.2 Equations 258 12.3.3 Exemp/e 282 12.4 TRAPPES D'EXTRACTIONDES FUMEES ..•..•.•..•.•.••......•...•...••.....•••.•••...•..••.•.•..•. ; 286 12.4.1 /ntroductlon 286 12.4.2 Travaux antérieurs de rA/PCR 288 12.4.3 Objectlfs des trappes d'extraction des fumées 288 12.4.4 Caractéristlques defonctionnement " 292 12.4.5 Spécificatlons 306 12.4.6 Fonctlonnement 310 12.4.7 Essals uploads/Management/ ewo-100-v-5-a-pdf.pdf

  • 23
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager
  • Détails
  • Publié le Apv 29, 2022
  • Catégorie Management
  • Langue French
  • Taille du fichier 9.3483MB