V400 installation guide 1 V Ampli ?er Mainframe V ?tted with x M Ampli ?er Modules for illustrative purposes only Installation Guide ASL Document Ref U- - doc Issue complete approved - Date Part Number M CV ?? Installation Guide This equipment is designed

V Ampli ?er Mainframe V ?tted with x M Ampli ?er Modules for illustrative purposes only Installation Guide ASL Document Ref U- - doc Issue complete approved - Date Part Number M CV ?? Installation Guide This equipment is designed and manufactured to conform to the following EC standards EMC EN - E EN - E EN - ENV EN - - Safety EN Failure to use the equipment in the manner described in the product literature will invalidate the warranty A ? Declaration of Conformity ? statement to the above standards and a list of auxiliary equipment used for compliance veri ?cation is available on request This product must be disposed of in accordance with the WEEE directive Contents Installation Connection Safety and Precautions Additional User Documentation Additional reference information is available from the ASL website www asl-control co uk Copyright ? Application Solutions Safety and Security Limited Application Solutions Safety and Security Limited Unit Cli ?e Industrial Estate Lewes - East Sussex BN JL - UK Tel Fax www asl-control co uk All rights reserved Information contained in this document is believed to be accurate however no representation or warranty is given and Application Solutions Safety and Security Limited assumes no liability with respect to the accuracy of such information Issue complete approved Page of CV ?? Installation Guide Installation AMPLIFIER MODULE FRAME INTERFACE CARD Technical Speci ?cation Summary Supply Voltage European standard V ?? RMS Hz AC T A L V fuse See Note regarding performance when on V mains supply Inrush Current worst case A Maximum AC Power Consumption VA V fully con ?gured and all ampli ?er modules delivering V kHz sinewave into rated resistive loads DC Supply Voltage to V from nominal V lead acid battery pack T A fuse Quiescent DC Current no ampli ?ers V supply mA Maximum DC Current Consumption A per x M W Ampli ?er Module A per x M W Ampli ?er Module A per x M W Ampli ?er Module V supply modules delivering V kHz sinewave into rated resistive loads Audio Input up to four dBu sensitivity balanced audio inputs Audio Output up to four V RMS relay isolated outputs Auxiliary DC Supply Output V to V depending on AC or DC supply and battery conditions T A fuse Audio-CAN Bus up to ampli ?er mainframes Temperature Range storage and operating ?? C to C Humidity Range Ingress Protection to non- condensing IP Dimensions H x W x D mm x mm x mm excluding handles U height ? rack mounting mm x mm x mm including handles Weight kg V frame only kg max frame ?tted with x M ASL ampli ?ers are speci ?ed to deliver their rated power at the lowest battery voltage V However on V mains power they can produce full output with normal programme material into loads greater than those speci ?ed In these conditions a fully populated V can deliver full output with W of load connected Issue complete

Documents similaires
Abecedart bill viola Bill Viola Une synthèse non exhaustive sous forme d'abécédaire des éléments qui peuvent aider à comprendre son ?uvre A Auto ?lmage L'immortalité et l'éternité sont abordées dans deux ?uvres Man Searching for Immortality Woman Searchin 0 0
Image de l allemagne a travers un choix de bandes dessinees franco belges 1960 1980 0 0
Grammaire francaise 1 RETOUR À INDEX GÉNÉRAL DU GUIDE DE GRAMMAIRE GUIDE DE GRAMMAIRE FRANÇAISE MORPHOSYNTAXE Guilherme Ribeiro DISCOURS STYLE DIRECT DISCOURS STYLE INDIRECT EXEMPLES -- FORMES VERBALES INTRODUCTOIRES -- VD d' ORDRE -- PERSONNELS -- POSSES 0 0
Pfc2008 06 guide 1 La syllabation et le rel? chement des voyelles hautes en syllabe non ?nale en français québécois Marie-Hélène Côté Université d'Ottawa ? mhcote uottawa ca Phonologie du français contemporain Structures des français en contact Tulane Uni 0 0
Td2 Université Med Khider ??Biskra- Faculté des sciences et de la technologie Département de chimie industrielle Matière thermodynamique des équilibres ieme LMD TD Exercice Calculer la variance des systèmes suivants CaCO s CaCO s CO g Fe O s H g Fe s H O 0 0
Devoir 6primaire fr s2 serie2 pdf 0 0
Plaquette web 1 sommaire ÉDITO LES RENDEZ-VOUS DE LA SAISON ÈRE PARTIE DE SAISON ÈME PARTIE DE SAISON ÈME PARTIE DE SAISON ACTIONS CULTURELLES ÉTABLISSEMENTS SCOLAIRES ABONNEMENT INFOS PRATIQUES ET TARIFS VIE CULTURELLE MENTIONS DE PRODUCTION CALENDRIER D 0 0
Ces grands createurs qui ont revolutionne la mode 0 0
Document 2 TITRE DU RAPPORT AVRIL NOM DE LA SOCIÉTÉ Créé par Votre nom CTitre de l ? en-tête Texte du sous-titre ici Pour commencer immédiatement appuyez simplement sur le texte d ? un espace réservé tel que celui-ci puis commencez à taper pour remplacer 0 0
Epreuve ecrite 2 ÉPREUVE ÉCRITE no Remplace les espaces libres avec les formes convenables du subjonctif présent a Je voudrais vous sortir dans la ville avec moi b Il est possible que mon docteur être en retard c Nous sommes surpris que tu avoir cet avant 0 0
  • 28
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager