Controle de la pression de pregonflage des accumulateurs pdf

CONTRÔLE DE LA PRESSION DE PREGONFLAGE DES ACCUMULATEURS ACCUMULATORS PRE-INFLATION PRESSURE CHECKING GENERALITE La pression de prégon age d ? un accumulateur est de ou bars bars à oC ou MPa MPa à oC Cette pression varie suivant la température ambiante On peut dire qu ? à une variation de température de oC correspond approximativement une variation de la pression de voir abaque ci-après La pression de prégon age à oC est indiquée sur le cylindre de l ? accumulateur NOTA MPa bar Pression e ?ective E ?ective pressure MPa bar psig GENERAL The pre-in ation pressure in the accumulator is ou bars bars at oC ou MPa MPa at oC This pressure varies with ambient temperature For a oC temperature variation the corresponding pressure variation is approximately see chart below The pre-in ation pressure at oC is stamped on the accumulator cylinder NOTE MPa bar bar psig MPa oC oF Température Temperature RÉALISATION - REALIZATION FARIS VISA - VISA BRASSOD PAGE - PAGE REV--DATE - REV-DATE C FASCICULE - SECTION K - C MESURAGE DE LA PRESSION DE PREGONFLAGE Disjoncteur ??ouvert ? alimentation électrique du groupe moto-pompe hors tension Sur l ? ensemble de regon age monter le bloc de contrôle robinets K et K fermés sur le clapet Relier par un tube vinyl diamètre intérieur mm la sortie BP du bloc de contrôle à l ? ori ?ce de remplissage du réservoir - Ramener la pression du circuit hydraulique à zéro en ouvrant les robinets K puis K du bloc de contrôle - L ? opération ci- dessus terminée refermer le robinet de vidange K du bloc de contrôle le robinet K est ouvert et alimente le manomètre - Mettre la pompe en fonctionnement quelques secondes en surveillant le manomètre du bloc de contrôle Dès la mise en route de la pompe la pression monte très rapidement puis se stabilise La valeur lue au moment de la stabilisation correspond à la pression d ? azote A ?n de mieux apprécier la valeur mesurée répéter deux ou trois fois l ? opération de contrôle Si la pression relevée est hors tolérances e ?ectuer le changement de l ? accumulateur PRE-INFLATION SUREMENT PRESSURE MEA- With the circuit-breaker ??open ? the electric power supply of the motor-pump unit interrupted Place the pressure checking block with cocks K and K closed on the valve in the re-in ation unit Connect using the vinyl tube with inside diameter mm the LP outlet of the contol block to the receiver ?lling port - Bring the hydraulic circuit pressure to zero by opening the pressure checking block ? s cocks K then K - When the above operation is ?nished close the drain cock K of the pressure checking block cock K is open and feeds the pressure gauge - Start the pump let it run for a few seconds whilst watching the BCP ? s pressure gauge From the pump ? s starting the pressure will rise quickly then become stable The stable value

Documents similaires
Projet de Développement des Ressources Humaines des Régions / Human Resources D 0 0
Maitre de conferences en droit public a l x27 institut d x27 etudes politiques de strasbourg france 0 0
Mainsail Insignia Guide - Page 1 210 420 470 505 Abbott 22 Able 20 Aero B Alaju 0 0
Tk guide Transitional Kindergarten IMPLEMENTATION GUIDE A Resource for California Public School District Administrators and Teachers Governor ? s State Advisory Council on Early Learning and Care Sacramento t CThis page intentionally blank CTransitional K 0 0
Tbw32 pdf 1 Sage Telbac Version Manuel de référence ? Sage CComposition du progiciel Votre progiciel est composé d'un bo? tier de rangement comprenant ? le cédérom sur lequel est enregistré le programme ? la documentation électronique présente sur le cédé 0 0
Examens de mécanique -1ère Année S.T A.Chafa, F. Mekideche-Chafa, A. Dib, A. De 0 0
Apprendre a reussir 1 C C CAndré Giordan Jérôme Saltet Apprendre à réussir J ? ai lu Librio Flammarion ? E J L Dépôt légal septembre ISBN numérique ISBN du pdf web Le livre a été imprimé sous les références ISBN Ce document numérique a été réalisé par PCA 0 0
Commentaire d'arrêt, CE 22 mars 2000, M. et Mme Lasaulce. Dans cet arrêt du 22 0 0
Mémoire de stage / Juin 2010 Diplôme national de master Domaine – sciences huma 0 0
Excavator spec guide EXCAVATOERXSCPAVECATGOURIDSEPEC GUIDE Excavators are only pro ?table if they are working when needed and can be coste ?ciently maintained in peak operating condition As such manufacturers are building in features designed to keep equi 0 0
  • 34
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager
  • Détails
  • Publié le Nov 23, 2022
  • Catégorie Administration
  • Langue French
  • Taille du fichier 29.1kB