Bacnet integration guide BACnet Integration Guide For an LGR line ME-LGR line or ME u-LGR controller Rev Verify that you have the most current version of this document Go to http accounts automatedlogic com then select Support Download Third-party Interfa
BACnet Integration Guide For an LGR line ME-LGR line or ME u-LGR controller Rev Verify that you have the most current version of this document Go to http accounts automatedlogic com then select Support Download Third-party Interfaces Third-party Integration Guides CContents Overview Before-you-begin checklist The integration process Discover BACnet networks devices and objects Create a control program Edit a control program Con ?gure Display microblocks Con ?gure Network Input and Total Analog microblocks Method BACnet COV subscriptions Method Polling To speed detection of a dead device Connect the third-party device to the ALC controller To wire a BACnet ARC device To wire a BACnet MS TP device To wire a BACnet PTP device Download the BACnet driver Verify the controller is set up correctly To capture ARCNET or MS TP communication To capture BACnet IP or BACnet Ethernet communication Appendix A - BACnet addresses Appendix B - To reuse a control program Appendix C - Third- party points behind NAT routers Appendix D - Point packs Appendix E - COV subscription details ? Automated Logic Corporation All rights reserved throughout the world Automated Logic Corporation the Automated Logic logo WebCTRL EIKON BACview SuperVision and InterOp are registered trademarks and Alert is a trademark of Automated Logic Corporation BACnet is a registered trademark of ASHRAE All other brand and product names are trademarked by their respective companies COverview You can integrate BACnet devices into a WebCTRL system using one of the ALC controllers listed below that provide third-party points The ALC controller serves as a master device ALC Controllers Read write capability Third party Supported equipment Supported media LGR LGR LGR- ME-LGR ME-LGR ME u-LGR points Can read from and write to the third-party equipment Any device that supports the BACnet protocol IP Ethernet ARC MS TP or kbps and PTP The point allowance of a controller the number after the letter R applies only to that controller For example if you purchase an LGR- that provides third-party points and you download control programs that use third-party Network I O points you cannot apply the unused points to a di ?erent controller If you have legacy ALC controllers that use point packs see Appendix D page Before-you-begin checklist You need the following items information and F F skills for the integration process The system's SiteBuilder database The F ALC controller's Technical Instructions The third-party device's ? BACnet network number and MAC address or the Device instance ? Points list including BACnet Object ID's object type plus object instance If the third party device is not installed or commissioned yet ask the third-party vendor for this information Then use Appendix A page to write correct BACnet F address strings in your microblocks The baud rate of the third-party F device if running MS TP Veri ?cation that all communication settings have F been set on the third-party device Experience creating control programs F with EIKON LogicBuilder Experience installing wiring setting up and downloading to the ALC controller BACnet Integration Guide ? Rev
Documents similaires










-
32
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Aucune attribution requise- Détails
- Publié le Jul 28, 2021
- Catégorie Management
- Langue French
- Taille du fichier 104.3kB