Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS-160) | Release 3.

Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS-160) | Release 3.1 Installation Guide Alcatel-Lucent – Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. 8DG09019HAAA JUNE 2009 ISSUE 1 Alcatel-Lucent - Proprietary See notice on first page. Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2009 Alcatel-Lucent. All Rights Reserved. Conformance statements Interference Information: Part 15 of FCC Rules This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interferences when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If the equipment is not installed and used in accordance with the guidelines in this document, the equipment may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the expense of the user. Security statement In rare instances, unauthorized individuals make connections to telecommunications networks through the use of remote access feature. In such an event, applicable tariffs require that the customer pay all network charges for traffic. Alcatel-Lucent cannot be responsible for such charges and will not make any allowances or give any credit for charges that result from unauthorized access. Limited warranty Alcatel-Lucent provides a limited warranty to this product. For terms and conditions of sale, contact your Alcatel-Lucent Account Team. 8DG09019HAAATQZZA Alcatel-Lucent – Proprietary iii June 2009 See notice on first page. Contents About this document vii Purpose........................................................................................................................................................vii Reason for revision.....................................................................................................................................vii Intended audience.......................................................................................................................................vii How to use this document ..........................................................................................................................vii Safety information ......................................................................................................................................vii Caution to avoid equipment damage............................................................................................................x Conventions used.........................................................................................................................................xi Related information....................................................................................................................................xii Document support......................................................................................................................................xiii Technical support ......................................................................................................................................xiii How to order..............................................................................................................................................xiii How to comment .......................................................................................................................................xiii Packaging collection and recovery requirements .....................................................................................xiii Recycling/take-back/disposal of product...................................................................................................xv 1 Mechanical installation of shelves into the Alcatel-Lucent TSS ETSI rack 1-1 Overview....................................................................................................................................................1-1 Mechanical installation of the Alcatel-Lucent 1850 TSS-320 subrack into the TSS rack......................1-2 Mechanical installation of the Alcatel-Lucent 1850 TSS-160 sub-rack into the TSS rack...................1-15 2 Electrical installation rules 2-1 Overview....................................................................................................................................................2-1 Alcatel-Lucent 1850 TSS-320 boards installation and electrical connections ......................................2-10 Alcatel-Lucent 1850 TSS-320 connection points - common unit..........................................................2-11 Alcatel-Lucent 1850 TSS-320 connection points - SDH units ..............................................................2-12 Alcatel-Lucent 1850 TSS-320 connection points - DATA units ...........................................................2-15 Alcatel-Lucent 1850 TSS-320 connection points – Optical Amplifier units.........................................2-18 Alcatel-Lucent 1850 TSS-320 connection points - DWDM unit...........................................................2-19 Alcatel-Lucent 1850 TSS-320 connection points – CWDM units.........................................................2-21 Power supply & synchronization ............................................................................................................2-24 iv Alcatel-Lucent - Proprietary 8DG09019HAAATQZZA See notice on first page. June 2009 Power supply connection ........................................................................................................................2-25 GENTRU power connection...................................................................................................................2-27 Synchronization connections ..................................................................................................................2-32 EC320 unit connection............................................................................................................................2-38 MATRIX unit connection .......................................................................................................................2-39 Back panel electrical connections...........................................................................................................2-46 Rack lamp connection .............................................................................................................................2-47 Remote alarm connection........................................................................................................................2-50 Housekeeping connection .......................................................................................................................2-52 Shelf ID connection.................................................................................................................................2-54 STEP-UP connections.............................................................................................................................2-56 Auxiliary channel connection .................................................................................................................2-60 Electrical cables routing..........................................................................................................................2-62 Fiber routing ............................................................................................................................................2-63 Alcatel-Lucent 1850 TSS-160 boards installation and electrical connections ......................................2-64 Alcatel-Lucent 1850 TSS-160 connection points - common units........................................................2-65 Alcatel-Lucent 1850TSS-160 connection points - SDH units ...............................................................2-67 Alcatel-Lucent 1850 TSS-160 connection points – DATA units ..........................................................2-70 Alcatel-Lucent 1850 TSS-160 connection points – Optical Amplifier units.........................................2-73 Alcatel-Lucent 1850 TSS-160 connection points – DWDM units ........................................................2-74 Power supply & synchronization ............................................................................................................2-77 GENTRU Power supply connection.......................................................................................................2-78 GENTRU power connection...................................................................................................................2-80 MANGTRU power supply connection...................................................................................................2-84 Synchronization connections ..................................................................................................................2-90 EC320 unit connection............................................................................................................................2-96 MATRIX unit connection .......................................................................................................................2-97 Electrical connections............................................................................................................................2-103 STEP-UP A/B cable ..............................................................................................................................2-106 Rack lamp cable ....................................................................................................................................2-107 Housekeeping cable pin-out..................................................................................................................2-108 Electrical cable routing..........................................................................................................................2-109 Fiber routing ..........................................................................................................................................2-111 Fiber conveyor installation....................................................................................................................2-112 8DG09019HAAATQZZA Alcatel-Lucent - Proprietary v June 2009 See notice on first page. Optical jumper routing ..........................................................................................................................2-113 3 Optical fiber 3-1 Overview....................................................................................................................................................3-1 Placing/removing devices into the sub-rack .............................................................................................3-2 4 Migration from Rel.1.x to Rel.3.x in Alcatel-Lucent 1850 TSS rack 4-1 Overview....................................................................................................................................................4-1 Safety rules ................................................................................................................................................4-2 Migration hardware procedure (greenfield)..............................................................................................4-3 Migration description ................................................................................................................................4-7 Migration hardware procedure (upgrade) ...............................................................................................4-11 20G packet processors to packet modules migration .............................................................................4-13 HO to HO+LO migration (MT320LO and LOAs).................................................................................4-17 A Suggested cables A-1 Overview...................................................................................................................................................A-1 B Installation kit B-1 Overview...................................................................................................................................................B-1 8DG09019HAAATQZZA Alcatel-Lucent – Proprietary vii June 2009 See notice on first page. About this document Purpose This manual provides instructions for installation and testing of the Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS-160). This manual is not a service manual. Refer to 8DG09019KAAA — Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS-160) User Provisioning Guide for any activities involving circuit turn-up, or 8DG09019CAAA — Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS- 160) Maintenance and Trouble Clearing Guide for trouble analysis and regular maintenance. In addition of this manual, read also the local documentation, especially about the electrical cables. Reason for revision This is the first issue of this document. It regards the Release 3.1 ETSI. Intended audience This manual is intended for individuals who are responsible for the installation, acceptance, operations, and maintenance of the Alcatel-Lucent 1850 TSS-320 and TSS- 160, How to use this document This manual is divided into several chapters and appendices. The first chapter contains safety information and general installation information. The other chapters provide instructional steps for personnel needing additional detail or background information. This document describes Alcatel-Lucent 1850 TSS-320 and TSS-160 operations. Refer to the Table of Contents to locate specific information by chapter. Safety information For your safety, this document contains safety statements. Safety statements are given at points where risks of damage to personnel, equipment, and operation may exist. Failure to follow the directions in a safety statement may result in serious consequences. viii Alcatel-Lucent - Proprietary 8DG09019HAAATQZZA See notice on first page. June 2009 Safety precautions Adhere to the following safety precautions: Electrostatic discharge (ESD) You must be properly grounded when making contact with the Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS-160) frame and handling circuit packs, disk drives, and tapes. Wrist strap ground cords should be routinely tested for the minimum 1- megohm resistance. The code of the Wrist strap is AD 03406 0001. Plug-in storage Circuit packs should be stored in static-safe packaging or in a grounded cabinet. For additional safety precautions, please see the Safety Guide. General Rules Check that the equipment is operating with all the shields properly positioned (dummy covers, ESD connector protections, etc.). Carefully observe the front-panel warning labels prior to working on optical connections while the equipment is in-service. To reduce the risk of damaging the electrostatic sensitive devices, it is mandatory to use the elasticized band (worn around the wrist) and the coiled cord connected to the rack ground when having to touch the equipment. FIXING THE UNITS (AND MODULES) INTO THE SUBRACK (caution to avoid equipment damage) The screw tightening torque for fixing the units (and modules, if any and if screw- fastened) into the subrack must be: 2.8 kg x cm (0.28 Newton x m) ± 10 % Exceeding this value may result in screw breaking. Rules for shielded cables WARNING: The intra-building port(s) of the equipment or subassembly is suitable for connection to intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the Outside plant or its wiring. These interfaces are designed for use as intra-building interfaces only and require isolation from the exposed Outside plant cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to Outside plant wiring. Equipment heat release 8DG09019HAAATQZZA Alcatel-Lucent - Proprietary ix June 2009 See notice on first page. Due to high heat release of the TSS-320 and TSS-160 equipments, special room cooling is required. Electrostatic discharge Electrostatic discharge (ESD), caused by touching with the hand for example, can destroy semiconductor components. The correct operation of the complete system is then no longer assured. Industry experience has shown that all semiconductor components can be damaged by static electricity that builds up on work surfaces and personnel. The electrostatic discharge can also affect the components indirectly via contacts or conductor tracks. The electrostatic charges are produced by various charging effects of movement and contact with other objects. Dry air allows greater static charges to accumulate. Higher potentials are measured in areas with low relative humidity, but potentials high enough to cause damage can occur anywhere. ESD instructions Observe the following ESD instructions to avoid damage to electrostatic-sensitive components: • Assume that all solid-state components and assemblies are sensitive to ESD. • Wear working garment made of conductive (ESD safe) not entirely cotton to avoid electrostatic charging. • Touch the circuit packs at the edges or the insertion and removal facilities only. • Touch the SFP modules at the edges only. • Ensure that the rack is grounded. • Wear a properly grounded ESD wrist strap (connected to the rack bonding point, for example). • Work in an ESD safe work area or workstation. An ESD uploads/s3/ installation-guide-r3-1.pdf

  • 22
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager