E4416 programming guide Programming Guide Agilent Technologies EPM-P Series Power Meters Agilent Technologies Part no E - Fourth Edition March C ? Copyright ?? Agilent Technologies All rights reserved Reproduction adaptation or translation without prior w
Programming Guide Agilent Technologies EPM-P Series Power Meters Agilent Technologies Part no E - Fourth Edition March C ? Copyright ?? Agilent Technologies All rights reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Printed in Malaysia ii EPM-P Series Power Meters Programming Guide CEquipment Operation WARNING Caution WARNING Equipment Operation Warnings and Cautions This guide uses warnings and cautions to denote hazards A warning calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in injury or the loss of life Do not proceed beyond a warning until the indicated conditions are fully understood and met A caution calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in damage to or the destruction of part or all of the equipment Do not proceed beyond a caution until the indicated conditions are fully understood and met Personal Safety Considerations This is a Safety Class I product provided with a protective earthing ground incorporated in the power cord The mains plug shall only be inserted in a socket outlet provided with a protective earth contact Any interruption of the protective conductor inside or outside the instrument is likely to make the instrument dangerous Intentional interruption is prohibited If this instrument is not used as speci ?ed the protection provided by the equipment could be impaired This instrument must be used in a normal condition in which all means of protection are intact only No operator serviceable parts inside Refer servicing to quali ?ed personnel To prevent electrical shock do not remove covers For continued protection against ?re hazard replace the line fuse s only with fuses of the same type and rating for example normal blow time delay etc The use of other fuses or material is prohibited EPM-P Series Power Meters Programming Guide iii CGeneral Safety Considerations WARNING Caution General Safety Considerations Before this instrument is switched on make sure it has been properly grounded through the protective conductor of the ac power cable to a socket outlet provided with protective earth contact Any interruption of the protective grounding conductor inside or outside the instrument or disconnection of the protective earth terminal can result in personal injury Any adjustments or service procedures that require operation of the instrument with protective covers removed should be performed only by trained service personnel User Environment The product is suitable for indoor use only iv EPM-P Series Power Meters Programming Guide CAbout this Guide About this Guide Chapter Power Meter Remote Operation This chapter describes the parameters which con ?gure the power meter and helps you determine settings to optimize performance Chapter MEASurement Instructions This chapter explains how to use the MEASure group of instructions to acquire data using a set of high level instructions Chapter CALCulate Subsystem This chapter explains how to use the CALCulate subsystem to perform post acquisition data processing Chapter CALibration Subsystem
Documents similaires










-
40
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Attribution requise- Détails
- Publié le Jui 09, 2022
- Catégorie Administration
- Langue French
- Taille du fichier 1MB