Supplement to: A1000 Quick Start Guide TOEPC71061641C <2> YASKAWA AC Drive-A100

Supplement to: A1000 Quick Start Guide TOEPC71061641C <2> YASKAWA AC Drive-A1000 High Performance Vector Control Drive Manual Supplement SUPPLEMENT NO. TOEP YEASUP 03A Models: 200 V Class: 0.4 to 110 kW (3/4 to 175 HP ND) 400 V Class: 0.4 to 630 kW (3/4 to 1000 HP ND) 600 V Class: 0.75 to 185 kW (1 to 250 HP ND) To properly use the product, read this supplement thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this supplement. 1 2 3 4 5 6 7 8 A B C D E 1 2 3 4 5 6 7 8 A B C D E Supplement to: P1000 Quick Start Guide TOEYAIP1U01A YASKAWA AC Drive P1000 Industrial Fan and Pump Drive Manual Supplement Type: CIMR-PU A Models: 200 V Class: 3/4 to 175 HP ND 400 V Class: 3/4 to 500 HP ND 600 V Class: 2 to 250 HP ND Type: CIMR-AU A 2 YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 1 Supplemental Information - Applicable Documents YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 3 1 Supplemental Information - Applicable Documents ‹ Document Applicability The contents of this supplement replace or add to the contents of the product manual sections listed in Table 1. Table 1 Affected Documents and Sections Yaskawa Product Document Chapter Section AC Drive - A1000 Quick Start Guide No. TOEP C710616 41C <2> and prior Preface & General Safety Safety Messages (revised) Chapter 1 - Receiving Nameplate (revised) Chapter 2 - Mechanical Installation Installation Environment (revised), Dimensions (added)) Appendix A - Specifications A.5 Drive Derating Data (added) Appendix C - Standards Compliance UL and CSA Standards (revised) Technical Manual No. SIEP C710616 41C <2> and prior Preface & General Safety Safety Messages (revised) Chapter 1 - Receiving Nameplate (revised) Chapter 2 - Mechanical Installation Installation Environment (revised), Dimensions (added) Appendix A - Specifications A.5 Drive Derating Data (revised) Appendix D - Standards Compliance UL and CSA Standards (revised) AC Drive - P1000 Quick Start Guide No. TOEP YAIPIU 01A Preface & General Safety Safety Messages (revised) Chapter 1 - Receiving Nameplate (revised) Chapter 2 - Mechanical Installation Installation Environment (revised), Dimensions (added)) Appendix A - Specifications A.5 Drive Derating Data (added) Appendix C - Standards Compliance UL and CSA Standards (revised) Technical Manual No. SIEP YAIP1U 01A Preface & General Safety Safety Messages (revised) Chapter 1 - Receiving Nameplate (revised) Chapter 2 - Mechanical Installation Installation Environment (revised), Dimensions (added) Appendix A - Specifications A.5 Drive Derating Data (revised) Appendix D - Standards Compliance UL and CSA Standards (revised) 4 YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 2 Supplemental Information - Preface - Safety Messages 2 Supplemental Information - Preface - Safety Messages W ARNING Fire Hazard - Drive Short-Circuit Current Rating Install adequate branch circuit protection according to applicable local codes and this Installation Manual. Failure to comply could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes, 240 Vac maximum (200 V class) and 480 Vac maximum (400 V class), and 600 Vac maximum (600 V class) when protected by branch circuit protection devices specified in this supplement. 3 Supplemental Information - Receiving - Applicable Models YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 5 3 Supplemental Information - Receiving - Applicable Models The A1000 and P1000 models listed in Table 2 are affected by this supplement. Table 2 Applicable A1000 and P1000 Models Voltage Class Model Number CIMR-†U† A 200 V 2A0004 2A0006 2A0008 2A0010 2A0012 2A0018 2A0021 2A0030 2A0040 2A0056 2A0069 2A0081 2A0110 2A0138 2A0169 2A0211 2A0250 2A0312 2A0360 2A0415 400 V 4A0002 4A0004 4A0005 4A0007 4A0009 4A0011 4A0018 4A0023 4A0031 4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165 4A0208 4A0250 4A0296 4A0362 4A0414 4A0515 4A0675 4A0930 <1> 4A1200 <1> <1> Not available in P1000 series. 600 V 5A0003 5A0004 5A0006 5A0009 5A0011 5A0017 5A0022 5A0027 5A0032 5A0041 5A0052 5A0062 5A0077 5A0099 5A0125 5A0145 5A0192 5A0242 6 YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 4 Supplemental Information - UL and CSA Standards 4 Supplemental Information - UL and CSA Standards ‹ UL and CSA Standards Compliance The UL/cUL mark applies to products in the United States and Canada. It indicates that UL has performed product testing and evaluation, and determined that their stringent standards for product safety have been met. For a product to receive UL certification, all components inside that product must also receive UL certification. Figure 1 Figure 1 UL/cUL Mark This drive is tested in accordance with UL Standard for Safety UL508C and complies with UL requirements. The conditions described below must be met to maintain compliance when using this drive in combination with other equipment. ‹ A1000 & P1000 Factory Recommended Branch Circuit Protection Yaskawa recommends installing one of the following types of branch circuit protection to maintain compliance with UL508C. Semiconductor protective type fuses are preferred. Alternate branch circuit protection devices are also listed in Table 3. Table 3 A1000 & P1000 Factory Recommended AC Drive Branch Circuit Protection Drive Model A1000 and P1000 in Normal Duty Mode (Parameter C6-01 =1 <6>) A1000 in Heavy Duty Mode <7> (Parameter C6-01 =0) Nominal Output Power HP AC Drive Input Amps MCCB Rating Amps <1> Time Delay Fuse Rating Amps <2> Non-time Delay Fuse Rating Amps <3> Bussman Semi-conductor Fuse Rating (Fuse Ampere) <4> Nominal Output Power HP AC Drive Input Amps MCCB Rating Amps <1> Time Delay Fuse Rating Amps <2> Non-time Delay Fuse Rating Amps <3> Bussman Semi-conductor Fuse Rating (Fuse Ampere) <4> 240 V Models 2†0004 0.75 3.9 15 6.25 10 FWH-70B (70) 0.75 2.9 15 5 8 FWH-70B (70) 2†0006 1 - 1.5 7.3 15 12 20 FWH-70B (70) 1 5.8 15 10 15 FWH-70B (70) 2†0008 2 8.8 15 15 25 FWH-70B (70) 2 7 15 12 17.5 FWH-70B (70) 2†0010 3 10.8 20 17.5 30 FWH-70B (70) 2 7.5 15 12 20 FWH-70B (70) 2†0012 3 13.9 25 20 40 FWH-70B (70) 3 11 20 17.5 30 FWH-70B (70) 2†0018 5 18.5 35 30 50 FWH-90B(90) 3 15.6 25 25 40 FWH-90B(90) 2†0021 7.5 24 45 40 70 FWH-90B(90) 5 18.9 35 30 50 FWH-90B(90) 2†0030 10 37 60 60 110 FWH-100B (100) 7.5 28 50 40 75 FWH-100B (100) 2†0040 15 52 100 90 150 FWH-200B (200) 10 37 60 60 100 FWH-200B (200) 2†0056 20 68 125 110 200 FWH-200B (200) 15 52 100 90 150 FWH-200B (200) 2†0069 25 80 150 125 225 FWH-200B (200) 20 68 125 110 200 FWH-200B (200) 2†0081 30 96 175 150 275 FWH-300A (300) 25 80 150 125 225 FWH-300A (300) 2†0110 40 111 200 175 300 FWH-300A (300) 30 82 150 125 225 FWH-300A (300) 2†0138 50 136 250 225 400 FWH-350A (350) 40 111 200 175 250 FWH-350A (350) 2†0169 60 164 300 250 450 FWH-400A (400) 50 136 250 225 350 FWH-400A (400) 2†0211 75 200 400 350 600 FWH-400A (400) 60 164 300 250 450 FWH-400A (400) 2†0250 100 271 500 450 800 FWH-600A (600) 75 200 400 350 600 FWH-600A (600) 2†0312 125 324 600 500 800 FWH-700A (700) 100 271 500 450 800 FWH-700A (700) 2†0360 150 394 700 600 1000 <5> FWH-800A (800) 125 324 600 500 900 <5> FWH-800A (800) 2†0415 175 471 900 800 1400 <5> FWH-1000A (1000) 150 394 700 600 1100 <5> FWH-1000A (1000) 4 Supplemental Information - UL and CSA Standards YASKAWA TOEP YEASUP 03 Yaskawa AC Drive - A1000 & P1000 Manual Supplement 7 480 V Models 4†0002 1 2.1 15 3.5 6 FWH-40B (40) 0.75 1.8 15 3 5 FWH-40B (40) 4†0004 2 4.3 15 7.5 12 FWH-50B (50) 1 - 2 3.2 15 5 9 FWH-50B (50) 4†0005 3 5.9 15 10 17.5 FWH-70B (70) 3 4.4 15 7 12 FWH-70B (70) 4†0007 3 8.1 15 12 20 FWH-70B (70) 3 6 15 10 17.5 FWH-70B (70) 4†0009 5 9.4 15 15 25 FWH-90B (90) 5 8.2 15 12 20 FWH-90B (90) 4†0011 7.5 14 25 20 40 FWH-90B (90) 5 10.4 20 17.5 30 FWH-90B (90) 4†0018 10 20 40 35 60 FWH-80B (80) 7.5 - 10 15 30 25 40 FWH-80B (80) 4†0023 15 24 45 40 70 FWH-100B (100) 10 20 40 35 60 FWH-100B (100) 4†0031 20 38 75 60 110 FWH-125B (125) 15 29 50 50 80 FWH-125B (125) 4†0038 25 44 75 75 125 FWH-200B (200) 20 39 75 60 110 FWH-200B (200) 4†0044 30 52 100 90 150 FWH-250A (250) 25 - 30 47 75 75 125 FWH-250A (250) 4†0058 40 58 100 100 150 FWH-250A (250) 30 43 75 75 125 FWH-250A (250) 4†0072 50 71 125 110 200 FWH-250A (250) 40 58 100 100 150 FWH-250A (250) 4†0088 60 86 150 150 250 uploads/s3/ yaskawa-a1000-installation-guide.pdf

  • 12
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager