Zebra® Real Time Clock Reference Guide © 2006 ZIH Corp. The copyrights in this
Zebra® Real Time Clock Reference Guide © 2006 ZIH Corp. The copyrights in this manual and the software and/or firmware in the label printer described therein are owned by ZIH Corp. Unauthorized reproduction of this manual or the software and/or firmware in the label printer may result in imprisonment of up to one year and fines of up to $10,000 (17 U.S.C.506). Copyright violators may be subject to civil liability. This product may contain ZPL®, ZPL II®, and ZebraLink™ programs; Element Energy Equalizer® Circuit; E3®; and Monotype Imaging fonts. Software © ZIH Corp. All rights reserved worldwide. ZebraLink and all product names and numbers are trademarks, and Zebra, the Zebra logo, ZPL, ZPL II, Element Energy Equalizer Circuit, and E3 Circuit are registered trademarks of ZIH Corp. All rights reserved worldwide. All other brand names, product names, or trademarks belong to their respective holders. For additional trademark information, please see “Trademarks” on the product CD. Proprietary Statement This manual contains proprietary information of Zebra Technologies Corporation and its subsidiaries (“Zebra Technologies”). It is intended solely for the information and use of parties operating and maintaining the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the express, written permission of Zebra Technologies Corporation. Product Improvements Continuous improvement of products is a policy of Zebra Technologies Corporation. All specifications and designs are subject to change without notice. Liability Disclaimer Zebra Technologies Corporation takes steps to ensure that its published Engineering specifications and manuals are correct; however, errors do occur. Zebra Technologies Corporation reserves the right to correct any such errors and disclaims liability resulting therefrom. Limitation of Liability In no event shall Zebra Technologies Corporation or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any damages whatsoever (including, without limitation, consequential damages including loss of business profits, business interruption, or loss of business information) arising out of the use of, the results of use of, or inability to use such product, even if Zebra Technologies Corporation has been advised of the possibility of such damages. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Part Number: 47867L-005 Rev. A 11/8/06 Real Time Clock Reference Guide 47867L-005 Rev. A Contents Document Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv 1 • Control Panel Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Real Time Clock Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Idle Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 RTC Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 RTC Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 • RTC ZPL II Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 RTC General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 First Day of the Week Affects Calendar Week . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Time and Date Precision. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 ZPL II Samples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Contents Document Scope iv 47867L-005 Rev. A Real Time Clock Reference Guide 11/8/06 Document Scope This guide contains the information needed to install, program, and operate the Real Time Clock (RTC) option. This hardware option is available as either a factory-installed or field-installable option in specific printer products manufactured and sold by Zebra Technologies Corporation. The Real Time Clock option is currently available for following printers, and requires that the firmware version shown is installed on that printer. Supported Zebra Printer and Print Engine Models Requires this Firmware Version or Higher 105SL printers that meet any one of the following criteria: • if the printer was manufactured after April 2006 • if the RTC Date and the RTC Time fields are printed on the configuration label • if the RTC Date and the RTC Time appear on the LCD display 60.13.0.13Z DA402 & T402 printers 32.8.4 LP2844-Z, TPL2844-Z, and TPL3844-Z printers 45.10.x PAX Series print engines 170PAX2 print engines 29.9.x or 31.9.x 110PAX3 print engines using Standard Font 34.10.x 110PAX3 print engines using TT Font 49.10.x 116PAX3 print engines using TT Font 35.10.x 170PAX3 print engines using Standard Font 37.10.x 170PAX3 print engines using TT Font 38.10.x 110PAX4 and 170PAX4 print engines 60.13.0.12 S4M printers 50.13.x S600 printers 27.10.3 Xi Series printers 90XiII, 140XiII, 170XiII & 220XiII printers 18.9.x 90XiIII, 96XiIII, 140XiIII, 170XiIII, and 220XiIII printers 33.10.0 90XiIIIPlus, 96XiIIIPlus, 140XiIIIPlus, 170XiIIIPlus, and 220XiIIIPlus printers 60.13.0.12 Z4Mplus and Z6Mplus printers 60.13.0.12 11/8/06 Real Time Clock Reference Guide 47867L-005 Rev. A 1 Control Panel Programming New parameters for the Real Time Clock have been added to the Control Panel Configuration. These parameters are located immediately following the FORMAT CONVERT prompt. Refer to the printer/print engine User Guide for complete configuration information. • X.9.x firmware added the parameters to XiII printers and 170PAX/170PAX2 print engines. • X.10.x firmware added the parameters to XiIII printers and PAX3 print engines. • X.13.x firmware added the parameters to XiIIIPlus printers, PAX4 print engines. • X.13.0.13Z firmware added the parameters to 105SL printers. Control Panel Programming Real Time Clock Parameters 2 47867L-005 Rev. A Real Time Clock Reference Guide 11/8/06 Real Time Clock Parameters The parameters listed on the following pages are added to the Control Panel Configuration prompts only when both the Real Time Clock hardware option and the appropriate version of firmware are installed: • X.9.x or above firmware installed in the XiII series printers or the 170PAX/170PAX2 series print engines. • X.10.x or above firmware installed in the XiIII series printers or the PAX3 series print engines. • X.13.0.13Z or above firmware installed in the 105SL printers • X.13.x or above firmware installed in the XiIIIPlus series printers, the PAX4 series print engines, or the S4M printers. The RTC ZPL II commands apply to all printers/print engines with the Real Time Clock hardware option and proper firmware (see Document Scope on page iv for printers/print engines and firmware versions). Idle Display Selects the printer/print engine Idle Display format and the method of uploads/Science et Technologie/ rtc-guide.pdf
Documents similaires










-
25
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Attribution requise- Détails
- Publié le Fev 20, 2021
- Catégorie Science & technolo...
- Langue French
- Taille du fichier 0.3034MB