Institut International d’Ingénierie Rue de la Science - 01 BP 594 - Ouagadougou

Institut International d’Ingénierie Rue de la Science - 01 BP 594 - Ouagadougou 01 - BURKINA FASO Tél. : (+226) 50. 49. 28. 00 - Fax : (+226) 50. 49. 28. 01 - Mail : 2ie@2ie-edu.org - www.2ie-edu.org MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA MEMOIRE POUR L’OBTENTION DU MASTER EN INGENIERIE DE L’EAU ET DE L’ENVIRONNEMENT OPTION : GENIE ENERGETIQUE ET ELECTRICITE ------------------------------------------------------------------ Présenté et soutenu publiquement le [Date] par Damaud Ulrich ANDI Travaux dirigés par : FRANCIS SEMPORE : Enseignant à l’Institut International d’Ingénieries de l’Eau et de l’Environnement (2ie) ADJAKA KOUAMI : Ingénieur de conception directeur général de l’entreprise HILEC & CO Jury d’évaluation du stage : Président : BAGRE Ahmed Membres et correcteurs : SEMPORE Francis ABOUBAKAR Gomna Promotion [2014/2015] MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA I ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 DEDICACES A mon père Michel ANDI, pour ton soutien inconditionnel et pour cette grande confiance que tu as toujours eu à mon égard. A ma défunte mère Pauline N’djia N’GBELE, pour ton inconditionnel accompagnement et la motivation que tu as su inculquer en moi. A mes tendres et très chères grandes sœurs Henriette ANDE, Thérèse ANDE, pour votre bienveillance, votre aide et vos conseils précieux. A mes chers grands frères Daniel ANDI, Antoine COMOE pour votre bienveillance et vos conseils précieux A mes petits frères Noel Andi, Wilfried ANDI, et ma petite sœur Yvonne ANDI pour vos encouragements A tous les membres de ma famille pour votre soutien. MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA II ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 REMERCIEMENTS Le présent mémoire est le fruit de 06 mois de travail. Il a été réalisé avec la contribution de plusieurs personnes à qui, je tiens à exprimer tous mes sincères remerciements. J’exprime ma profonde gratitude à Monsieur Kouami ADJAKA Directeur Général de l’entreprise HILEC & CO, qui a été mon maître de stage, pour la confiance qu’il m’a accordée au sein de son entreprise, son encadrement, sa patience et pour le temps qu’il a accepté de me consacrer lors du stage malgré son emploi du temps chargé. Son expérience et son savoir-faire m’ont permis de découvrir de nombreuses facettes du métier d’ingénieur. Merci pour le soutien et la supervision que vous m’avez apportés tout au long de ce stage. Je témoigne également toute ma reconnaissance à Mr Francis SEMPORE, mon directeur de Mémoire pour avoir dirigé mes travaux et la confiance dont il a fait preuve à mon égard. Je remercie les enseignants de 2iE pour le savoir obtenu pendant ma formation. Je remercie spécialement Nina ZERBO et Léa ZERBO, Pour le soutien moral qu’elles m’ont apporté durant la rédaction de mon mémoire. Je remercie ma collègue stagiaire Francine MAWAMBA pour le soutien moral et sa disponibilité. Je remercie Mr BAMBA Abdoulaye, Mr DIARRA Sambo de SEEE, Mr Isaïe SAWADOGO de BECOTEX pour tout le soutien et l’aide professionnelle qu’ils m’ont donné durant mon stage et pendant la rédaction de mon mémoire. MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA III ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 RESUME/ABSTRACT RESUME Un bâtiment bien conditionné est un élément qui peut permettre de booster la productivité dans le travail aussi bien dans le tertiaire que dans l’industrie. Cependant, une mauvaise conception, une défaillance au niveau du fonctionnement, et un vieillissement du système de climatisation peuvent entrainer une baisse de cette productivité et également une augmentation de la consommation énergétique due à ces équipements. C’est dans cette optique que l’UEMOA a décidé de changer le système de climatisation de son siège, qui a été installé en 1978. Le changement d’un système de climatisation dans les anciens bâtiments nécessite une grande ingénierie et une attention particulière doit être portée aux différentes normes qui règlementent l’installation du système de climatisation. Pendant la désinstallation de l’ancien système de l’UEMOA, une attention a été portée sur la récupération du fluide frigorigène R22 afin qu’elle soit conforme à la norme NF EN 35421. L’installation du système VRV (Volume Réfrigérant Variable) a été réalisée conformément à la norme NF EN 378 et celle du système de ventilation a été conforme à la norme DTU 68. La méthode utilisée pour le contrôle d’étanchéité des tuyauteries frigorifiques est la méthode de chute de pression conformément à la norme NF EN 13184. La protection électrique des appareils a été réalisée conformément à la norme NF C 15 – 100. A la fin de l’installation, le système a été mis en service pendant deux semaines. Après cette mise en service, une pré réception a été effectuée ; celle-ci a été suivie d’une visite technique, ensuite la réception provisoire a été prononcée. La principale réserve formulée à la fin de la réception provisoire porte sur Installation des ventilateurs extracteurs. En outre il a été formulé des recommandations et des propositions sur l’exécution des travaux et sur la réception, qui portent sur les travaux et la réception, la lutte contre l’incendie l’efficacité énergétique, la maintenance Mots clés : 1) rénovation, 2) productivité, 3) climatisation, 4) recommandation, 5) norme. MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA IV ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 ABSTRACT A well-conditioned building is a factor which can help booster the productiveness in service industry. However, a wrong design, a functioning breakdown and an air conditioning aging can cause productiveness decrease and an increase of energy consumption due to those equipment. Within this context, UEMOA has decided to change the air conditioning system of its head office which was installed in 1978. Air conditioning system renewal in outmoded buildings requires a high engineering and a particular attention may be paid to different standards that regulate air conditioning installation. During UEMOA outmoded system unsetting, an attention was paid to R22 refrigerating fluid recuperation in order to conform it to NF EN 35421 standard. VRV (Variable Refrigerating Volume) system installation was realized in accordance with NF EN 378 norm and that of ventilation system was conform to DTU 68. Implemented method for air tightness control of refrigerating pipings’ was pressure drop method in accordance with NF EN 13184 standard. Electric protection of equipment was in agreement with NF C 15 – 100 standard. In the end of the installation, the system was implemented for two weeks. After this implementation, an acceptance test and a technical visit were done before a tentative reception was pronounced. The main reserve was formulated in the end of the tentative reception. It was about fan extractors’ installation. In addition, recommendations and suggestions were made when it has come to work implementation, reception, conflagration, energy effectiveness and maintenance. Keywords: 1) Renovation, 2) Productiveness, 3) Air conditioning, 4) Recommendation, 5) Standard. MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA V ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 LISTE DES SIGLES ET DES ABREVIATIONS CEAO : Communauté des Etats de l'Afrique de l'Ouest CTA : Centrale de Traitement d’Air DTU : Documents Techniques Unifiés EP : Evacuation pluviale EN : Norme Européenne FOSIDEC : Fonds de Solidarité et d’Intervention pour le Développement de la Communauté Economique de l’Afrique de l’Ouest NF : Norme Française GWP : Global Warning Potential PAO : Potentiel d’Appauvrissement de la couche d’Ozone UEMOA : Union Economique et Monétaire d’Afrique de l’Ouest VMC : Ventilation Mécanique Contrôlée VRV : Volume de Réfrigérant Variable SEEE Société d'Eudes et Entreprise D’équipement SOGETEL Société Générale de Travaux et de constructions Électriques MISE EN ŒUVRE D’UN SYSTEME DE CLIMATISATION VRV : CAS DU SIEGE DE L’UEMOA VI ANDI DAMAUD ULRICH / Master II d’ingénierie en Génie Electrique et Energétique/2014 - 2015 SOMMAIRE DEDICACES .............................................................................................................................. i REMERCIEMENTS .................................................................................................................. ii RESUME/ABSTRACT ............................................................................................................. iii LISTE DES SIGLES ET DES ABREVIATIONS ..................................................................... v SOMMAIRE ............................................................................................................................. vi LISTES DES TABLEAUX ....................................................................................................... ix LISTE DES FIGURES ............................................................................................................... x INTRODUCTION .................................................................................................................... 11 I. PRESENTATION DE L’ENTREPRISE HILEC & CO .................................................. 12 I.1 Présentation de l’entreprise ....................................................................................... 12 I.2 Rôle de HILEC & CO dans la rénovation du siège de l’UEMOA ............................ 12 II. Parties prenantes et travaux préliminaires ..................................................................... 13 II.1 Parties prenantes ........................................................................................................ 13 II.1.1 Maître d’ouvrage ................................................................................................ 13 II.1.2 Maitre d’ouvrage délégué ................................................................................... 13 II.1.3 Maître d’œuvre ................................................................................................... 13 II.1.4 Entreprise exécutante ......................................................................................... 14 II.1.5 Bureau de contrôle technique ............................................................................. 14 II.2 Travaux préliminaires ................................................................................................ 14 II.2.1 Étude et élaboration du planning ........................................................................ 14 II.2.2 Aménagement d’un site ...................................................................................... 16 II.2.3 Libération des bureaux ....................................................................................... 16 II.2.4 Commande des appareils .................................................................................... 16 III. DESINSTALLATION ET CONTROLE DES TRAVAUX DE L’ANCIEN SYSTEME 18 III.1 Dépose du système à eau glacée ................................................................................ 18 III.1.1 Dépose du groupe de production d’eau glacée ................................................... 18 III.1.2 Dépose des tuyauteries et des ventilo uploads/Geographie/ andi-damaud-ulrich.pdf

  • 35
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager