Modbus integration guide Modbus Integration Guide For an LGR line ME-LGR line or ME u-LGR controller Rev Verify that you have the most current version of this document Go to http accounts automatedlogic com then select Support Download Third-party Interfa
Modbus Integration Guide For an LGR line ME-LGR line or ME u-LGR controller Rev Verify that you have the most current version of this document Go to http accounts automatedlogic com then select Support Download Third-party Interfaces Third-party Integration Guides CContents Overview Controller as a master device on EIA- Before-you- begin checklist The integration process Create a control program in EIKON LogicBuilder Formatting a Modbus address Editing a microblock address Download the Modbus driver and control programs Connect the Automated Logic controller to the third-party device Wiring speci ?cations To wire a third-party device Set up the Modbus Combo driver properties Verify the controller is set up correctly To capture communication using PuTTY Controller as a slave device on EIA- Before-you- begin checklist The integration process Create a control program in EIKON LogicBuilder Formatting a Modbus address Editing a microblock address Download the Modbus driver and control programs Connect the Automated Logic controller to the third-party device Wiring speci ?cations To wire a third-party device Set up the Modbus Combo driver properties Verify the controller is set up correctly To capture communication using PuTTY Controller as a client device on Ethernet Before-you- begin checklist The integration process Create a control program in EIKON LogicBuilder Formatting a Modbus address Editing a microblock address Download the Modbus driver and control programs Connect the Automated Logic controller to the third-party device Set up the Modbus Combo driver properties Verify the controller is set up correctly To capture communication using Wireshark To capture communication using PuTTY Controller as a server device on Ethernet Before-you-begin checklist The integration process Create a control program in EIKON LogicBuilder Formatting a Modbus address Editing a microblock address Download the Modbus driver and control programs Connect the Automated Logic controller to the third-party device Set up the Modbus Combo driver properties Verify the controller is set up correctly To capture communication using Wireshark To capture communication using PuTTY ? Automated Logic Corporation All rights reserved throughout the world Automated Logic WebCTRL EIKON and BACview are registered trademarks and EnergyReports Environmental Index and Eco-Screen are trademarks of Automated Logic Corporation BACnet is a registered trademark of ASHRAE All other brand and product names are trademarked by their respective companies CModbus Troubleshooting If the Automated Logic controller is a Serial Master or Ethernet Client Register addresses Errors If the Automated Logic controller is a Serial Slave or Ethernet Server Register addresses Errors Appendix A - Upgrading an existing Modbus driver Appendix B - Modbus Protocol Conformance Statement C COverview You can use an Automated Logic controller to integrate Modbus device s with a WebCTRL system The controller can serve as a master or slave on a serial network or a client or server on a TCP IP network This document is divided into sections that provide integration instructions for the scenarios listed in the ?rst two columns below Determine how your Automated Logic controller will be used then go to the appropriate page for the instructions If the Automated on this
Documents similaires










-
27
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Aucune attribution requise- Détails
- Publié le Mar 30, 2021
- Catégorie Management
- Langue French
- Taille du fichier 175.8kB