Article04 24 Article Original EFFET DE L ? ANTICOAGULANT ET DE LA CONSERVATION DES ECHANTILLONS SANGUINS SUR LES TESTS D ? EXPLORATION DE LA COAGULATION EFFECT OF ANTICOAGULANT AND STORAGE OF BLOOD SAMPLES FROM CLOTTING EXPLORATION TESTS N LOUATI I BEN AM
Article Original EFFET DE L ? ANTICOAGULANT ET DE LA CONSERVATION DES ECHANTILLONS SANGUINS SUR LES TESTS D ? EXPLORATION DE LA COAGULATION EFFECT OF ANTICOAGULANT AND STORAGE OF BLOOD SAMPLES FROM CLOTTING EXPLORATION TESTS N LOUATI I BEN AMOR G DAOUED et J GARGOURI CRTS de Sfax - Tunisie Faculté de médecine université de Sfax-Tunisie Email de l ? auteur correspondant nourlouati yahoo fr Résumé La ?abilité des tests de l'hémostase est fortement dépendante du respect des conditions pré- analytiques Nous avons évalué sur plasmas l'impact de la concentration et et de la proportion du citrate de sodium trisodique rapports volume anticoagulant sang V V V V et V V ainsi que des conditions de conservation du prélèvement délais et températures sur les tests de la coagulation taux de prothrombine TP temps de céphaline activateur TCA dosage du ?brinogène Fg facteur V FV et facteur VIII coagulant FVIIIc Résultats in uence variable des di ?érentes conditions pré-analytiques sur les tests de coagulation Le citrate à M donne des activités basses du FV Les valeurs moyennes des TP TCA Fg FV et FVIIIc ont été plus abaissées après conservation des plasmas pendant jours à C que celles obtenues après conservation pendant jours à - C Le choix de la concentration du citrate est préférable en termes de ?abilité des résultats La conservation des plasmas à - C assure une meilleure stabilité de l ? activité des facteurs de la coagulation Une étude sur une population plus large plus diversi ?ée et incluant d ? autres tests de l ? hémostase permettra de consolider ces résultats et tester d ? autres variables pré-analytiques Mots clés anticoagulant conservation hémostase variables pré-analytiques Abstract The reliability of hemostasis testing is highly dependent on respect to pre-analytical variables We evaluated on plasmas the e ?ect of sodium citrate concentration and and proportion ratios of anticoagulant to blood V V V V and V V as well as sample storage conditions time and temperatures on the results of coagulation testing prothrombin time PT activated partial thromboplastin time aPTT ?brinogen Fg concentration factor V FV and VIII coagulant FVIIIc activities Results variable in uence of the di ?erent pre-analytical conditions on coagulation testing M citrate produced low activities of FV The average values of PT aPTT Fg FV and FVIIIc were lowered after the storage of plasmas for days at - C than those obtained after storage for days at - C The choice of citrate concentration is preferable in terms of results's reliability Plasmas specimens kept at - C had better stability of the activity of factors of coagulation A study on a larger and more diversi ?ed population and including other hemostasis testing is required to consolidate these results and to test other preanalytical variables Key words anticoagulant haemostasis pre-analytical variables storage ?? ? ?? ? ? ?? ? ?? ? ?? ? ? ?? ? ? ? ? ? ? ? ?? ? ? ? ? ? ? ?? ?? ? ? ? ??
Documents similaires










-
41
-
0
-
0
Licence et utilisation
Gratuit pour un usage personnel Aucune attribution requise- Détails
- Publié le Aoû 06, 2022
- Catégorie Health / Santé
- Langue French
- Taille du fichier 116kB